Reinstall in reverse order.
The Multiair blower should be stored in dry, noncorro-
sive atmosphere, at temperature between -20 and +55 °C.
Service menu:
The service menu is accessible when the blower is in
operation or when stopped.
Press "Reset" for 4 sec., where after the display will
enter the service menu. All buttons become active,
whatever the DIP switch settings may be.
Scrolling up and down in the menu are done by press-
ing "+" or "-".
A sub menu are selected by pressing "Start".
A sub menu are cancelled by pressing "Stop".
To escape the sub menu, press "Reset". In case "Re-
set" is not pressed, the operator´s panel will automati-
cally escape the service menu after approximately 6
min.
After cancelling the service menu, all buttons are again
controlled by the DIP switch settings.
Main menu
"-H-"
"LOG"
"APP"
Sub menu "-H-"
Here is shown the accumulated number of hours, in
which the blower has been operating (where the AC
drive has been operating) - not the number of hours in
which the main switch has been on.
In the example below, the blowers has been operating
for 90.819 hours.
When "-H-"(Hours) has been selected, press "Start",
where after the number of hours above 1.000 will be
displayed. In this case "-90" without decimal separa-
tor. One press on "–" displays number of hours ranging
from 0-999, in this case "819" with decimal separator
above first digit (the ACT indicator).
It is possible to switch between the two selections by
pressing the "+" and "–" buttons. The "+" button will
display the first 3 digits (here "-90"), and the "–" button
will display the last 3 digits (here "819").
The menu is escaped by pressing "Stop" or "Reset".
Sub menu "LOG"
In case of errors and warnings, these are saved in the
control box.
Sub menu "ALL" (All) will display both errors and
warnings. Both location and the corresponding error/
12
warning code are displayed.
Sub menu "Err" (Error) will only display errors. Location
and the corresponding error code are displayed.
When "LOG" is selected, press "Start", where after
"ALL" is displayed. By pressing "+", "Err" is displayed.
When "ALL" is selected, press "Start", where after
first location (1) and code in the logfile is displayed, or
"EOF" (End Of File) in case no errors or warnings are
logged.
One press on "+" displays next location in the log, and
the corresponding code.
One press on "-" displays previous location in the log,
and the corresponding code.
When pressing "Start", the location and code are
repeated.
When no further errors or warnings are present, "EOF"
is displayed.
When "Err" is selected, press "Start", where after first
location (1) and error code in the logfile is displayed, or
"EOF" (End Of File) in case no errors are logged.
One press on "+" displays next location in the log, and
the corresponding error code.
One press on "-" displays previous location in the log,
and the corresponding error code.
When pressing "Start", the location and error code are
repeated.
When no further errors are present, "EOF" is displayed.
The menu is escaped by pressing "Stop" or "Reset".
Sub menu "APP"
Here is shown a 3 digit code for respectively the soft-
ware version on the operator´s panel, and the control
box.
When "APP" (Application) is selected, press "Start",
where after the software version for the operator´s
panel is displayed.
When pressing the "+" button, the software version for
the control box is displayed.
It is possible to switch between the two selections by
pressing the "+" and "–" buttons. The "+" button will
display the software version for the operator´s panel,
and the "–" button will display the software version for
the AC drive.
The menu is escaped by pressing "Stop" or "Reset".