The cable connections must be made in accordance with the wiring diagram on the
bottom of the hob.
-
Each type of cable must be connected to the corresponding power terminal box.
-
You must use a good quality screwdriver to carefully and completely tighten ALL terminal
screws.
-
If only two zones work when you switch on the hob for the first time, you should
double-check that all terminal screws are tightened securely. This must be done before
contacting the official Cecotec Technical Support Service.
Important
-
DO NOT connect the appliance to the mains using a 13 A plug and socket.
-
It must be connected to a 30 A double-pole fused socket outlet, with a contact separation
of 3 mm and located in an easily accessible place next to the appliance. It must not be
placed above the appliance or more than 1.25 m from the appliance.
-
The cable can be coiled, if necessary, but make sure that the cable is not kinked or
pinched when installing the hob. Do not allow the cable to come into contact with hot
parts of the appliance.
Replacing the power cable. Fig. 9
-
If the mains power cable is damaged, it must be replaced with a suitable one, please
contact the official Cecotec Technical Support Service or a qualified technician.
-
The power cable must be replaced according to the following instructions:
1. Switch off the appliance.
2. Open the terminal block located at the bottom of the hob.
3. Unscrew the terminal screws securing the cable.
4. The "green-yellow" earth cable must be connected to the marked terminal. It should be
about 10 mm longer than the power and neutral cables.
5. The "blue" neutral cable must be connected to the terminal marked with the letter (N) -
the power cable (L1) must be connected to the terminal marked with the letter (L1) (220-
240 V 1N~). Fig. 9
6. The "blue" neutral cable must be connected to the terminal marked with the letter (N) -
the L1 power cable must be connected to the terminal marked with the letter (L1). The L2
cable must be connected to the terminal marked with the letter (L2) (380-420V 2N~).
Fig. 9
4. OPERATION
1. Switch on
When the power is turned on, the hob will beep once to indicate that the power is on. Then, all
indicators on the display will light up for 2 seconds. Next, the appliance will go into shutdown
mode.