No: 341168– 03/16
Catalog Number(s) • Numéro(s) de Catalogue • Les Numéros de Catalogue: RRW600U
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
READ AND SAVE THESE INSTRUCTIONS
To be installed by a certified electrician or other qualified person.
WARNING – To prevent severe shock or electrocution, always turn
poweroff at the service panel before installing this product, working on the
circuit, or changing a lamp.
CAUTION
• Do not connect this product to a power source other than 120VAC,
60Hz.
• Use copper wire only.
Specifications
Load.......................................... Single Pole or 3 Way
Time Delay ............................... 30 Seconds to 30 Minutes
Environment ............................. Indoor Use Only
Tools Needed
Insulated Screwdriver, Wire Strippers
RRW600U
DESCRIPTION AND OPERATION
The RRW600U occupancy and vacancy sensor is designed to replace a
standard light or fan switch. The sensor uses passive infrared technology
to sense human motion in a space and turn the light OFF when the room
is vacant. It is ideal for applications in a home where there is a direct line
of sight from the sensor to the room, including bedrooms and family/living
rooms.
Occupancy Mode:
The load will automatically come ON when motion is detected, and turn
OFF automatically, at the desired time delay, if no motion is detected. If the
load is manually turned OFF, and motion is detected within 30 seconds,
the load will remain OFF until no motion has been detected for 30 seconds.
It can then automatically turn ON again once it detects motion. The
RRW600U allows the load to be turned ON manually as well, and turn OFF
automatically at the desired time delay, if no motion is detected.
Vacancy Mode:
In this mode, the load is required to be turned ON manually, and will
turn OFF at the desired time delay, if no motion is detected. If motion is
detected within 30 seconds after it automatically turns OFF, the RRW600U
automatically turns the load back ON.
USER SETTINGS
Table 1 – Time Delay Setting
Setting
Status
From User
LED or LOAD State
(Input to the device)
(Acknowledgement
from the device)
With the load ON or OFF,
LED will blink 5 times
hold down the ON/OFF
and then turn off
Initiate
button for 10 seconds
then release
Push down the ON / OFF
LED flashes quickly two
Time Delay
button first time.
times per 1.5s.
Adjustment
Push down the ON / OFF
LED flashes quickly
Mode – To
button second time
three times per 1.5s.
change the
amount of time
Push down the ON / OFF
LED flashes quickly four
Activate
before the
button third time
times per 1.5s.
sensor switch
Push down the ON / OFF
LED flashes quickly five
turns off after
button fourth time
times ON per 1.5s.
last movement
Push down the ON / OFF
LED flashes quickly one
button fifth time
time per 1.5s.
Hold down the ON / OFF
LED will blink 5 times
Save / Exit
button for 10 seconds
and then turn off
then release
Table 2 – RRW600U Occupancy/Vacancy Mode Adjustment
From User
Setting
Status
(Input to the device)
Initiate
With the load ON or OFF,
hold down the ON/OFF
button for 15 seconds
then release
Working Mode
Activate
Push down the ON /OFF
Setting: to
button first time
Change between
Occupancy Mode
Push down the ON /OFF
(Auto on) and
button second time
Vacancy Mode
(Manual On)
Save / Exit
Hold down the ON / OFF
button for 15 seconds
then release
The RRW600U has an onboard indicator LED located at the top of the unit This
indicator is used to show when motion is detected. The LED is also used while
programming the RRW600U and indicates STATUS during power up. The LED
is further used to indicate a malfunctioning unit. Both Occupancy and Vacancy
Modes can be programmed/selected to function with or without the LED
indicator if preferred by the user.
Table 3 – Status LED Enable/DIsable
LED or LOAD State
From User (Input to
Setting
Status
(Acknow ledgement
the device)
from the device)
When the
With the load ON or
LED will blink 5 times
LED is
OFF, hold down the
and then turn off
Enabled
ON/OFF button for
25 seconds
Enable and
disable the
status LED
When the
With the load ON or
LED will blink 5 times
indicator
LED is
OFF, hold down the
and then turn off
Disabled
ON/OFF button for
25 seconds
341168_RRW600U OccVac Sensor IS.indd 1
The RRW600U has a maximum
coverage range of 180 degrees
and a coverage area of 600 square
feet (56 square meters). The sensor
must have a clear and unobstructed
view of the coverage area. Objects
blocking the sensor's lens may
prevent detection thereby causing
the light to turn off even though
someone is in the area.
Windows, glass doors, and other
transparent barriers will obstruct
the sensor's view and prevent
detection.
1. Prepare the switch box.
After the power is turned off at the circuit breaker box, remove the existing wall
Result
plate and mounting screws. Pull the old switch out from the wall box.
2. Identify the type of circuit.
Enters
Single Pole
Time Delay
Adjustment Mode
In a Single Pole Circuit (see Figure
2), two single wires connect to two
Set the time delay to
screws on the existing switch. A
5 Minutes
ground wire may also be present
Set the time delay to
and connected to a ground terminal
10 Minutes
on the old switch.
Set the time delay to
3-Way
15 Minutes
In a 3-way circuit (see Figure 3),
Set the time delay to
there will be [2 runners and
30 Minutes
1 common] for both switches
Set the time delay
involved.
to 30 Seconds
Save / Exit Time
Delay Adjustment
Mode
LED or LOAD State
(Acknow ledgement
Result
from the device)
LED will blink 5 times
Enters
and then turn off
Working Mode
Setting Mode
LED flashes quickly
Set the Working
two times ON per 1s.
Mode to vacancy
sensor
Figure 3: 3-Way
LED flashes quickly
Set the
Figure 3: Trois voies
one time ON per 1s.
Working Mode
Figura 3: 3 Vías
to occupancy
sensor
CAUTION For your safety: Connecting a proper ground to the sensor provides
LED will blink 5 times
Save / Exit
protection against electrical shock in the event of certain fault conditions. If
and then turn off
Working Mode
Setting Mode
a proper ground is not available, consult with a qualified electrician before
continuing installation.
3. Prepare the Wires.
Tag the wires currently connected to
the existing switch, so that they can be
identified later. Disconnect the wires. Make
sure the insulation is stripped off the wires
to expose their copper cores to the length
indicated by the "Strip Gage," in Figure 3a.
Result
4. Wire the sensor.
1-pole configuration:
LED will Disable: locator light
Twist existing wires together
will be in an "On State" when
with the wire leads on the
the load is off and will not blink
RRW600U sensor as indicated
when motion is detected; the
below. Cap them securely
locator light will be in an "Off
using the wire nuts provided.
State" when the load is on and
See Figure 4.
will not blink when motion is
detected
• Connect the green or non-
LED will Enable: locator light
insulated (copper) GROUND
will be in an "On State" when
wire from the circuit to the
the load is off and will not blink
green ground wire on the
when motion is detected; the
RRW600U. Make sure there
locator light will be in an "Off
is a solid ground connection.
State" when the load is on
and will blink when motion is
• Connect the power wire
detected.
from the circuit (HOT)
to the black wire on the
RRW600U.
• Connect the power wire to
the lamp or fan (LOAD) to the red wire on the RRW600U.
Multilocation configuration (using existing companion 3-way switch):
see Figure 5.
• Connect the green or non-insulated (copper) GROUND wire from the circuit
to the green ground wire on the RRW600U. Make sure there is a solid
ground connection.
• Connect the power wire from the circuit (HOT) to the black wire on
the RRW600U.
• Connect the power wire to the lamp or fan (LOAD) to the red wire on
the RRW600U.
• Connect one of the runner wires to the yellow wire of the RRW600U.
• For the companion switch, connect the chosen runner wire (presently
hooked up to the yellow wire of the RRW600U) to the common of the 3-way
companion mechanical switch.
• Connect one of the poles of the companion 3-way switch to ground.
• For the remaining pole of the companion 3-way switch, do not connect to
anything, but still cap off with a wire nut.
Pass & Seymour
Occupancy/Vacancy Sensor Switch
Interrupteur à détection de présence/Interrupteur détecteur d'inoccupation
Interruptor de sensibilidad a la ocupación/Interruptor con sensor de "habitación vacía"
Incandescent/ELV: 600W ; CFL/LED: 450W; MLV: 600VA; ELV: 5A; Motor: 1/6 hp
Installation Instructions • Notice d'Installation • Instrucciones de Instalación
LIRE ET CONSERVER CES INSTRUCTIONS
Doit être installé par un électricien certifié ou une autre personne qualifiée.
AVERTISSEMENT – Pour éviter tout choc électrique ou une électrocution,
toujours couper l'électricité au niveau du panneau d'alimentation avant
d'installer cette unité, de travailler sur le circuit électrique ou de changer
une lampe.
AVERTISSEMENT
• Ne brancher ce produit qu'à une source d'alimentation de 120 V c.a.,
60 Hz.
• N'utiliser que des fils en cuivre.
Spécifications
Charge ...................................... Unipolaire ou à 3 voies
Temporisation ........................... 30 secondes à 30 minutes
Environnement ......................... Utilisation en intérieur uniquement
Outils nécessaires
Tournevis isolé, dénudeurs de fil
COVERAGE AREA
25'
(7.6m)
12'
(3.7m)
Figure 1: Sensor Coverage Area
Figure 1 : Zone de portée du détecteur
Figura 1: Área de cobertura del sensor
INSTALLATION & WIRING
Figure 2:
Single Pole
Figure 2: Pôle simple
Figura 2: Polo único
3-Way
In a 3-Way circuit, identify the Common/
Hot wire – connected to the terminal
marked Common or the odd-colored
terminal screw.
Trois voies (3-Way)
Pour un circuit à trois voies, identifier le
câble de commun/courant raccordé à la
borne marquée « Commun » ou à la vis
de borne de couleur différente.
3 vías
En un circuito de 3 vías, identifique el
cable Común/Vivo: conectado al terminal
marcado como Común o al tornillo del
terminal de color diferente.
Strip Gauge,
Borne à vis
Traseros para cables
Strip Gage
1/2"
1/2"
12.7mm
12.7mm
Figure 3a: Wire Stripping
Figure 3a : Dénudage des fils
Figura 3a: Pelado de cables
Neutral
Neutre
Neutro
Load
Charge
Carga
Line
Ligne
Linea
Black / Noir / Negro
Red
NC
Yellow / Jaune / Amarillo
Rouge
Rojo
Green / Vert / Verde
Ground
Terre
Tierra
Figure 4: Single Pole Configuration
Figure 4 : Configuration unipolaire
Figura 4: Configuración del polo único
®
LEA Y CONSERVE ESTAS INSTRUCCIONES
Para ser instalado por un electricista certificado o persona competente.
ADVERTENCIA – Para evitar descargas eléctricas serias o electrocución,
antes de instalar, trabajar en el circuito o cambiar una lámpara de este
atenuador apague siempre el suministro eléctrico en el panel de servicio.
PRECAUCIÓN
• No conecte este producto a una fuente de alimentación que no sea de
120 V AC, 60Hz.
• Use solamente cables de cobre.
Especificaciones
Carga ........................................ Polo único o de 3 vías
Tiempo de demora ................... 30 segundos a 30 minutos
Entorno ..................................... Solo uso en interiores
Herramientas necesarias
Destornillador aislado, pelacables
Neutral
Neutre
Neutro
Line
Black
Red
Ligne
Noir
Rouge
Linea
Negro
Rojo
Yellow
Ground
Green
Jaune
Terre
Vert
Amarillo
Tierra
Verde
Figure 5: 3-Way Configuration / Figure 5 : Configuration à 3 voies
Figura 5: Configuración de 3 vías
Multilocation configuration (using up to 5 units, maximum wire length of
100 ft between companion unit and unit connected to the load):
see Figure 6.
• Connect the green or non-insulated (copper) GROUND wire from the circuit
to the green ground wire on the RRW600U. Make sure there is a solid
ground connection.
• Connect the power wire from the circuit (HOT) to the black wire on
the RRW600U.
• Connect the power wire to the lamp or fan (LOAD) to the red wire on
the RRW600U.
• Connect one of the runner wires to the yellow wire of the RRW600U.
• For the companion RRW600U, connect the chosen runner wire (presently
hooked up to the yellow wire of the 1st RRW600U) to the yellow wire of the
companion RRW600U.
• Repeat for additional RRW600U units.
Neutral
Neutre
Neutro
Load
Charge
Carga
Line
Black
Red
Line
Line
Ligne
Noir
Rouge
Ligne
Ligne
Linea
Negro
Rojo
Linea
Linea
Yellow / Jaune / Amarillo
Ground
Green
Ground
Terre
Vert
Terre
Tierra
Verde
Tierra
Figure 6: Multilocation Configuration
Figure 6 : Configuration à plusieurs emplacements
Figura 6: Configuración de ubicación múltiple
5. Put the RRW600U in the wall box. Position the lens above the ON/OFF
button (lens at top, button at bottom). Secure it to the wall box with the
screws provided.
6. Make any necessary adjustments. See the SENSOR ADJUSTMENT section
for information.
7. Attach the new cover plate.
8. Restore power to the circuit. Turn on the breaker or replace the fuse.
INITIAL POWER UP DELAY
There is an initial warm-up (about 1 minute) and calibration period the first
time power is applied to the unit and after the load is replaced. The warm-up
sequence also occurs as a result of a power failure, and any time power to the
unit is cycled.
CHANGING THE COLOR OF THE UNIT
1. Remove the wallplate.
2. Firmly grasp the edges of
the front cover directly below
the lens where it says "open."
Push in one side first until it
pops out, then the other side.
Remove front cover from the unit
(see Figure 7).
3. Take the new color front cover,
place the top peg in first then
snap in each side one at a
Figure 9: Replace Front Cover
time (see Figure 9).
Figure 9 : Remplacement de
la protection avant
Figura 9: Reemplace la cubierta frontal
TROUBLESHOOTING
Status LED is enabled but not blinking and the load will not turn ON:
• Check the circuit breaker to be sure it is functioning.
• Check to make sure that the device is properly grounded. This device will not
function if it is not grounded.
Load will not turn ON:
Press ON/OFF button. The load should turn ON. If not:
• Check the light bulb and/or motor switch on the fan mechanism.
• Turn OFF power to the circuit then check wire connections.
• For further assistance call 800.223.4185 for technical support.
Load will not turn OFF:
Note: The time delay can be set from 30 seconds to 30 minutes. Ensure that
the time delay is set to the desired delay and that there is no movement within
the sensor's view for that time period.
• To quickly test the unit for proper operation, turn the time delay to minimum
and move out of the sensor's view. Lights should turn off after 30 seconds.
• Press the ON/OFF button. If load does not turn off, turn off power to the
circuit then check wire connections.
• For further assistance call 800.223.4185 for technical support.
Load
Charge
Carga
H1
NC
common
commun
común
H2
Black
Noir
NC
Negro
Red
Rouge
Rojo
Green
Vert
Verde
Tim
e
Mot
ion
Del
ay
30m
OFF
Blin
in.
k
20m
in.
30se
10m
5mi
c.
in.
n.
3/8/16 8:25 AM