connected directly to junction box. Do not
cut the conduit. À U.L - or CSA - listed
conduit connector must be provided at
each end of the power supply cable (at
the cooktop and at the junction box.)
A time delay fuse or circuit breaker is
recommended. Do not ground to a gas
pipe. Do not have a fuse in the grounding
or neutral circuit. Fuse both supply
(phase) lines.
G] IMPORTANT: improper
connection of aluminum house wiring
to the copper leads can result in a
serious problem.
National Fire Protection Association
Bat-ter/march Park Quincy,
Massachusetts 02269
A three-wire, single phase, 240 Volt 60
cycle elec-trical system (properly circuit
protected to meet Local Codes of NFPA
No.70) must be provided. Unit must
be properly grounded in accordance
with local wiring code. The chart below
recommends the minimum circuit
protector and wire size if the appli-ance
is the only unit on the circuit. If smaller
sizes of wire are used, the unit efficiency
will be reduced and a fire hazard may be
created. It is advisable that the electrical
wiring and hookup be accomplished by a
competent electrician.
Be sure your appliance is properly
installed and grounded by a qualified
technician. Ask your dealer to
recommend a qualified technician or an
authorized repair service. This cooktop
does not require a neutral connection.
If the cooktop Is to be completely
enclosed In a cabinet, feed the cooktop
cable through the opening in the cabi-
net. Make the electrical connection
following the appropriate steps for your
installation.
This appliance is manufactured with a
green ground wire connected to the
cooktop chassis. After making sure that
the power has been turned off, connect
the flexible conduit from the cooktop
to the junction box using a U.L. listed
conduit connector. Figures 13 and 14 and
the instructions provided below present
the most common way of connecting
the cooktops. Your local codes and
ordinances, of course, take precedence
over these instructions. Complete
electrical connections according to local
codes and ordinances
A DANGER: Risk of Electric
Shock, frame grounded to neutral of
appliance through a link.
Grounding through the neutral conductor
is prohibited for new branch-circuit
installations (1996 NEC)# mobile
homes#and recreational vehicles, or
in an area where local codes pro-hibit
grounding through the neutral conductor.
3-Wire branch circuit
Where local codes allow the connection
of ground wire from the cooktop to the
branch circuit neutral wire (gray or white
colored wire) proceed as follows (See fig-
ure 13).
1.
If local codes permit, connect the
green GROUND wire from the
cooktop to the branch circuit neutral
wire (gray or white col-ored wire).
2.
Connect the red and black leads from
the cooktop to the corresponding
leads in the junction box.
17 | EN