Tensão de alimentação
Supply voltage
F/N
F
1
3
DR
2
4
1
3
DJ
>
>
2
4
S
PT
1
2
M
1
FIGURE 8.2- SINGLE-PHASE ELECTRICAL
CONNECTION SCHEME (MOTOR WITH
THERMAL PROTECTION)
5. Assembly and adjustments:
ATTENTION
to read and understand all instructions found in the following pages of this manual. All adjustments must be
made as indicated in this manual and always with the drill disconnected from power.
5.1. Column assembly:
• Place the column set on the base.
• Align the holes of the column support with the base ones.
• Fix the column using the bolts supplied (Figure 8.3)
5.2. Table assembly:
• Remove the safety ring from the column
• Slide the table clamp with table connected to the toothed rack and its support.
• Tighten the clamp by turning the Table Crank (Figure 8.5).
• Install the safety ring
• Connect the crank handle to the rack, tighten the set screw with an Allen key (Figure 8.6)
•
For power drill FSC 25P lodge the table on the support hole already fixed on the factory column.
Ground
Terra
Responsabilidade
Responsibility
do cliente
of the customer
Plugue 2P+T
Plug 2p+g
ou chicote
To avoid injuries related to unexpected movements during the drill assembly, you have
Note:
- For motor protection, the orientations of Figure 8.2 must
be followed.
- The electrical network must not present voltage variations
superior to ± 10%.
- The voltage drop caused during the start-up must not be
superior to 10%.
- Use retarded fuse.
- Expenses related to installation and accessories are
client's responsibility.
DJ
Thermomagnetic circuit breaker
DR
Residual current device
F
Phase
N
Neutral
M 1~
Single phase electric motor
S
On/Off switch
PT
Thermal protector
49
Legend (Figure 8.2)