Descargar Imprimir esta página

Frigidaire CPDS3085PFE Instrucciones De Instalación página 10

Cocinas de dual fuel de 30"

Publicidad

Idiomas disponibles

Idiomas disponibles

Pressure
regulator location
Figure
9
Manual
GAS FLOW
Pressure
Shutoff
Flare
_
Flare
Regulator
Valve
Union
Union
,_
On' i_
t
_
Npptle_
......
Nipple
Flexible
Access
Off
Connector
Cap
All connections
must be wrench-tightened
Figure 10
Assemble the flexible connector from the gas supply
pipe to the pressure regulator in the following order:
1. manual shutoff valve (not supplied)
2. 1/2" nipple (not supplied)
3. 1/2" flare union adapter (not supplied)
4. flexible connector
(not supplied)
5. 1/2" flare union adapter (not supplied)
6. 1/2" nipple (not supplied)
7. pressure regulator (supplied)
The gas supply line to the shutoff valve should be
1/2" (1,27 cm) or 3/4" (1,9 cm) solid pipe.
The user must know the location of the main shutoff
valve and have easy access to it.
When using flexible gas conduit on the range, allow
sufficient slack to pull the range outside the cutout for
cleaning or servicing.
NOTE: Do not allow the flexible conduit to get pinched
between the wall and the range. To visually check,
remove the range drawer.
Use pipe-joint compound made for use with Natural
and LP/
t_
Propane gas
to seal all gas
connections.
If flexible
connectors
are used,
be certain
connectors
are not kinked.
Shutoff Valve -
Open position
Figure
11
The supply line must be equipped with an approved
manual shutoff valve. This valve should be located
in the same room as the range and should be in a
location that allows ease of opening and closing. Do
not block access to the shutoff valve. The valve is for
turning on or shutting off gas to the appliance.
Once regulator is in place, open the shutoff valve in the
gas supply line. Wait a few minutes for gas to move
through the gas line.
Leak testing
of the appliance
shall be conducted
according
to the manufacturer's
instructions.
Check for leaks. After connecting the range to the gas
supply, check the system for leaks with a manometer.
If a manometer is not available, turn on the gas
supply and use a liquid leak detector at all joints and
connections
to check for leaks.
Do not use a flame to check for leaks
from gas connections.
Checking for leaks with a flame
may result in a fire or explosion.
All openings in the wall or floor where the range is to
be installed must be sealed.
Tighten
all connections
if necessary to prevent gas
leakage in the cooktop or supply line.
Disconnect
this range and its individual shutoff
valve from the gas supply piping system during any
pressure testing of the system at test pressures greater
than 1/2 psig (3,5 kPa or 14" (35,56 cm) water column).
Isolate the range from the gas supply
piping
system
by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig
(3,5 kPa or 14" (35,56 cm) water column).
LP/Propane
Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with
natural gas.
If you wish to convert your range for use with LP/
Propane gas, use the supplied fixed orifices located
in a bag containing the literature marked "FOR
LP/PROPANE
GAS CONVERSION".
Follow the
instructions
packaged with the orifices.
The conversion must be performed by a qualified
service technician
in accordance with the
manufacturer's
instructions
and all local codes and
requirements.
Failure to follow these instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility
for the conversion.
Failure to make the appropriate
conversion
can result in personal injury and property
damage.
10

Publicidad

loading

Este manual también es adecuado para:

Fgds3065pfrFgds3065pfgFgds3065pfpCgds3065pfnFgds3065pfm