2) How to install the device
- The packaging comprises:
- 1 installation/operating manual
- 1 mounting kit:
- 1 bracket
- One bar and its installation instructions
The installation template is printed on the packaging.
1) Unfasten the carton's flaps and place it against the wall with the lower flap folded back and resting flat on he
floor. Prick out the four drill holes though the packaging (without drilling) and then remove the packaging.
2) Carefully mark the drilling points with a pencil (draw a cross, 4cm wide).
3) Drill the four holes.
4) Position the four hooks and screw them tight.
5) Attach the appliance and lock it in place.
1
Note: The pins supplied with the device are of the standard type. In case of a particular stand, use appropriate pins.
3) Connecting the device
- The device must be supplied with 230V, 50Hz.
- Mains connection must be ensured using a 3-wire cable
(Brown=Phase, Blue=Neutral, Black=Pilot wire), through
a connecting box. In damp premises, such as bathrooms
and kitchens, install the connecting box at least 25cm
from the ground.
- The installation must be equipped with a shutting-off devi-
ce in all poles having a distance of opening of contact of
at least 3mm.
- Ground connection is forbidden.
Do not connect the pilot wire (black) to ground.
- If power cable is damaged or too short, to avoid any danger it must be replaced by a qualified electrician
using special tools.
- If a device pilots or is piloted by a 30mA differential (e.g. bathroom), the pilot wire supply must be pro-
tected on this differential.
- 4 pins
8mm
- 4 wall mounts
- 4 stand securing screws
3
2
4
5
Panel heater cable
Phase=brown
PHASE
NEUTRAL
Neutral=blue
Pilot wire=Black
Two possible cases
The pilot wire end is insulated
1st case: only one heater
and not further connected
The pilot wire of all heaters in a
2nd case: multiple heaters
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm2 220-240V insulated cable
Electricity
grid