problems and solutions
The pump does not ignite.
Possible cause-The selector is in the O position
Solution-Select position I or II
Possible cause-The flow switch is dirty.
Solution-Remove the flow switch and provide maintenance.
Possible cause-Lack of electrical power.
Solution-Identify the thermomagnetic switch and is to set it.
Solution-False contact of the plug with the socket.
Possible cause-There is no water in the tub.
Solution-Check that the pressurizing pump has the minimum
pressure.
The pump doesn't stop.
Possible cause-The selector is in the manual position.
Solution-Move it to the automatic position.
Possible cause-The flow switch is dirty.
Solution-Remove the flow switch and provide maintenance.
The pump ignites but there is no pressure
Possible cause-Leakage in your hydraulic installation.
Solution-Inspect walls for moisture. In this situation the pump
should be turned on even if there is no open key.