global_main.book.book Page 9 Saturday, December 16, 2023 8:35 AM
Installing the Oven and
Test Run
Electrical Connections
3-Wire Circuit Connection
The oven must be connected by a licensed
specialist in accordance with these instructions and
in compliance with local regulations. Make sure the
voltage shown on the rating label is the same as
the power supply voltage in your home.
The oven must be connected to the power supply
by means of an all-pole disconnect switch with a
minimum contact gap of 3 mm and must be
connected to earthed socket by law. The supply
plug shall be accessible after the installation. The
oven's components operate at 230 V / 16 A. Identify
the phase and neutral conductor in the socket.
Incorrect connection may damage the oven.
Connect the oven to the power supply.
Live
a
b
Neutral
c
Earth
NOTE
• Connect the green and yellow ground wire to the
right terminal pole, the live brown wire to the left
terminal pole, and the neutral blue wire to the
center terminal pole.
INSTALLATION
9