Descargar Imprimir esta página

Style selections SRGF21626X Manual Del Usuario página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
lava rocks onto the fire pit.
Open the door panel (J)
Make sure the valve outlet of cylinder is facing outward.
(Fig. 10)
4. Turn the cylinder locking bolt clockwise to secure the gas
cylinder. (Fig. 11)
6
Your gas fire pit has been checked at all connections at the
factory for leakage.
In transportation and handling some connections may have
loosened. Follow these steps to check the hose/
regulator/cylinder connections:
1) Make leakage solution by mixing 1 part liquid dish soap and 3
parts water.
2) Spoon or brush several drops (or use squirt bottle) of the
solution onto hose/regulator/cylinder connection.
3) Turn on gas cylinder. Inspect the connections and look for
bubbles.
4) If no bubbles appear, the connection is safe.
5) If bubbles appear, there is leakage. Loosen and re-tighten this
connection. If there is still a leak, please call customer service:
1-877-888-8225.
Note:
1) The cylinder supply system must be arranged for vapor
withdrawal.
2) The cylinder used must include a collar to protect the cylinder
valve.
The hose assembly must be replaced prior to the appliance being
put into operation if there is evidence of excessive abrasion or
wear, or if the hose is damaged.
At least once a year, a complete inspection of the entire gas path
components should be performed.
If there is need to replace parts, proceed to leak test after
reassembly (These procedures should be performed by a profes-
sional technician).
12
13
13
10
11
12
Tighten
13
P2
regulator & cylinder
connection
P1

Publicidad