Installation
Instructions
[_
DETERMINING
WALL PLATE LOCATION UNDER YOUR CABINET
Plate
position
- beneath
flat bottom
cabinet
Plate
position
- beneath
framed
recessed
cabinet
bottom
MountingPlateTabs
the CabinetBottom
Mounting PlateTabs
Touchingthe Back
Frame
O
\
At least 30", up to 36"
Plate
position
- beneath
recessed
bottom
cabinet
with front
overhang
0
0
C
MountingPlatewith
TabsBelow Cabinet
Bottomthe Same
Distanceas the Front
Overhang Depth
1
30" to Cool<top
I
Your cabinets may have decorative trim that interferes
with the oven installation. Remove the decorative trim
to install the oven properly and to make it level.
THE OVEN MUST BE LEVEL.
Use a level to make sure the cabinet bottom is level.
If the cabinets have a front overhang only, with no back
or side frame, install the mounting plate down the same
distance as the front overhang depth. This will keep
the oven level.
[_
Measure the inside depth of the front overhang.
[_
Draw a horizontal line on the back wall an equal
distance below the cabinet bottom as the inside depth
of the front overhang.
[_
For this type of installation with front overhang only,
align the mounting tabs with this horizontal line, not
touching the cabinet bottom as described in Step D.