2. Ex marking / 3. Safety
2. Ex marking
DANGER!
Danger to life from explosion
Non-observance of these instructions and their contents may result in
the loss of explosion protection.
Installation and commissioning of the instrument in accordance with
manufacturer's specifications.
Observe the safety instructions in this chapter and further explosion
protection instructions in these operating instructions.
Observe the information given in the applicable type examination
certificate and the relevant country-specific regulations for installation
and use in hazardous areas (e.g. IEC 60079-14, NEC, CEC).
II 2G
Ex h IIC T6 ... T3 Gb X - 20 °C ≤ Ta ≤ + 60 °C X
II 2D
Ex h IIIC T85 °C ... T205 °C Db -20 °C ≤ Ta ≤ + 60 °C X
Check whether the classification is suitable for the application. Observe the relevant
national regulations.
3. Safety
3.1 Intended use
These thermometers are suitable for temperature measurement in hazardous areas in
sanitary applications.
The instruments have been designed and built solely for the intended use described
here, and may only be used accordingly.
Check whether the classification is suitable for the application, see Ex marking, chapter
3.4 "Labelling, safety markings". Observe the relevant national regulations.
The non-observance of the instructions for use in hazardous areas can lead to the loss
of the explosion protection. Adhere to the limit values and instructions; see data sheet
TM 58.01.
The manufacturer shall not be liable for claims of any type based on operation contrary
to the intended use.
WIKA additional operating instructions, model TG58SA (ATEX)