USING YOUR BLACKSTONE
BeFoRe CooKING
CHECK BURNERS
Prior to connection and use, ensure that there is no debris caught in,
or damage to, the head of the gas cylinder, regulator, hose, burner
and burner ports�
Spiders and insects can nest within and clog the burner/venturi tube
at the orifice�
Please reference the Troubleshooting chapter for burner cleaning
instructions�
Blocked burner
Blocked burner
Venturi
Venturi
Air intake
Air intake
Fuel nozzle
Fuel nozzle
Burner opening
Burner opening
Flammable items can combust if placed near the appliance.
Keep the appliance area clear and free from combustible
materials, aerosol containers, gasoline and other flammable
vapors and liquids.
THE MINIMUM AMBIENT OPERATING TEMPERATURE IS 0°F (-18°C).
10
WARNING
A clogged burner can
lead to a fire beneath the
appliance.
Burner should be removed
and cleaned whenever
blockages are found.
ensure that the gas
rail fuel nozzle orifice is
correctly engaged within the
burner opening�
dANGeR
SETTING UP YOUR OUTDOOR SPACE
THIS APPLIANCE MUST ONLY BE USED OUTDOORS.
• do NoT use this appliance inside buildings, garages, or any other
enclosed area�
• do NoT install this appliance in or on a boat�
• do NoT install this appliance in or on a recreational vehicle�
MAINTAIN PROPER CLEARANCES FROM COMBUSTIBLE MATERIAL.
• do NoT use this appliance on or under any apartment or condo-
minium balcony or deck�
• do NoT obstruct the flow of combustion and ventilation air�
• do NoT operate this appliance any closer than 36 in (1 m) from the
sides and back of the appliance to combustible construction�
A
A
A A
A A
A A
A A
A = 36 in (1 m)
A = 36 in (1 m)
• do NoT use this appliance under overhead combustible
construction�
SHELTERED OUTDOOR AREAS:
All openings must be permanently open; sliding doors, garage doors,
windows or screened openings are not considered as permanent
openings�
An appliance is considered to be outdoors if installed with shelter no
more inclusive than:
a. With walls on three sides, but
with no overhead cover�
b. Within a partial enclosure that
includes an overhead cover
and no more than two side-
walls� The sidewalls may be
parallel, as in a breezeway, or
at right angles to each other�
c. Within a partial enclosure that
includes an overhead cover
and three sidewalls, as long as
30% or more of the horizontal
periphery of the enclosure is
permanently open�
Model: 2287
Both ends open
Both ends open
30%
30%
30%
30%