Modello - Modèle - Model
Modell - Modelo - Modelo
Fabbricante - Constructeur - Manufacturer
Hersteller - Fabricante - Fabricante
8.1
Controller MPX-PRO30 - mod.
IR33C0HB00 (Carel)
1
2
5
3
4
8
1. Compressor
2. Fan
3. Defrost
4. Aux
5. Alarm
6. Clock
7. Lumière
8. Service
9. HACCP
10. Continuous cycle
11. Program/Mute
12. Up Arrow/Aux
13. Setpoint
14. Up Arrow/Def
Modification of Setpoint
• Press the button "Setpoint"(13)for over 1
sec. The value of the appears on the
display "Setpoint"(13).
• Increase, "Up Arrow"(12), or decrease,
"Up Arrow"(14), until reaching the value of
"Setpoint" desired.
• Press the button again "Setpoint"(13) to
confirm the new value.
Manual cycle start Defrost
• Press the button "Def"(14) for more than 2
(two)
seconds
conditions are verified)
N°DOC. UM000721 REV. "A" - 16/11/23
TWIN SV - TWIN MIDI SV
Epta Spa - Via Mecenate, 86 - 20138 Milano (MI) ITALIA
8.
CONTROL PANEL
6
7
11
12
9
10 13
14
Fig. 36
(only
if
the
defrost
Tel. 02/55403211 Telefax 02/55401023
8.2
Controller EW971EO (Eliwell)
1
5
2
9
15. Up Arrow
16. Up Arrow
17. Stand-by/Esc
18. Setpoint
19. Compressor
20. Defrost
21. Alarm
22. °F
23. Reduced set/Level 2 parameters
24. °C
25. Fan
26. Aux
Modification of Setpoint
• Press and instantly release the button
"Setpoint"(4).
• SET appears on the display.
• To change the value, act on the keys within
15 seconds "Up Arrow" (1)(to increase) or
"Up Arrow" (2)(to decrease).
• Press the button again "Setpoint"(4) and
the value of appears on the display
Setpoint.
Manual cycle start Defrost
• Press the button "Up Arrow" (1) for 5
seconds. If the conditions for defrosting
do not exist, the display flashes 3 times to
indicate that the operation will not be
carried out.