Every 250 operating hours
Replace air intake filter element of
compressor pump.
Replace air filter element of filter/
regulator unit.
Every 500 operating hours
Pump out oil through dip stick's
plastic pipe and fill in fresh oil.
Pumping can be done with a suita-
ble handpump or by an authorised
service station.
Every 1000 operating hours
Have unit serviced by an authorised
service station. This will extent the
compressor's service life considera-
bly.
5.2
Device storage
1.
Switch unit OFF and unplug.
2.
Release pressure from tank and all
connected air tools.
3.
Store device in such way that it can-
not be started by unauthorised per-
sons.
A
Caution!
Do not store device unpro-
tected outdoors or in damp environ-
ment.
Do not lay device on its side for trans-
portation or storing.
6. Trouble shooting
A
Danger!
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the device has come to
a complete stop.
− Ensure the device and all air tools
and accessories connected to it
are relieved from pressure.
− Let the device and all air tools
and accessories used cool off.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Compressor does not run:
No mains voltage.
− Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
− Use only extension cables of suf-
ficient lead cross section (see
"Technical specifications"). Avoid
using
extension
device is cold.
Compressor
was
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
Motor overheated, e.g. by insuffi-
cient cooling (cooling fins covered).
− Turn compressor OFF at the On/
Off switch. Remove cause for
overheating, let cool off for
approx. 10 minutes, then turn ON
again.
Compressor runs but does not build
up sufficient pressure.
Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain cock(s);
replace if necessary.
− Tighten drain cock(s) fingertight.
Drain cock on cup of filter/regulator
unit open.
− Tighten drain screw fingertight.
Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
Pressure regulator not opened wide
enough.
− Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.
8. Environmental protection
A
Danger!
The condensate from the pres-
sure vessel contains oil residue. Dis-
pose of the condensate environmen-
tally safe by taking it to a proper
collecting point!
A
Danger!
Dispose of the pump's crank-
case oil environmetally safe by taking
it to a proper collecting point!
The machine's packaging can be 100 %
recycled.
Worn out devices and accessories con-
cable
when
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
stopped
by
ENGLISH
These instructions are printed on paper
produced with elemental chlorine-free
bleaching process.
13