d)
Set the suction throttle to the closed position - the lever moved to the left.
When starting a warm engine, the intake throttle should be in the open
position - the lever moved to the right:
e)
Set the ignition switch on the control panel to the "ON" position.
f)
Grasp the starter jerk handle and slowly pull away from the unit until you
feel resistance, then pull with a firm motion, keeping the jerk handle in your
hand at all times even as it returns to the starting position. Repeat this
motion until the engine starts.
g)
Let the running engine work on the suction for about 1-3 minutes to reach
operating temperature.
h)
After the generator has warmed up, turn off the suction (smoothly move
the throttle valve to the open-right position).
i)
You can connect 230V AC receivers to the sockets, observing the rule to
connect in the order starting from the receiver requiring the highest
starting current to the lowest. When powering 12V receivers, connect them
to the correct poles before starting the generator, paying attention to the
correct polarity.
j)
Turn the installation switch to the "ON" position and you can use the
connected receivers.
3.3.3 Switching off the generator
a)
Turn off all power consumers connected to the device.
b)
Turn the installation switch to the "OFF" position.
c)
Also turn the ignition switch to the "OFF" position - this will turn off the
engine.
d)
Close the fuel valve - move its lever to the "OFF" position.
NOTE: in case of emergency shutdown of the generator: set the ignition
switch to the "OFF" position - the engine will go out. Then close the fuel
valve.