If the equipment is not to be used again, cool it down completely before
transporting. For transport, it is advisable to empty the fuel tank to prevent any
fuel leakage during transport.
If the unit is not used for a period of 1-2 months, empty the fuel from the tank
or pour fresh fuel and add stabilizer to it. If the unit is not used for more than a
few months, additionally empty the carburetor of fuel (dropping tank) and drain
oil from the engine. Do not keep fuel in the tank with stabilizer longer than
recommended by the manufacturer of this additive.
3.4.
Cleaning and maintenance
3.4.1 SERVICE INTERVALS TABLE
Action↓
Interval→
Control
Engine
oil
Replacement
Control
Air
filter
Replacement
Fuel
drop
Cleaning
filter
Inspection
Spark
and
plug
cleaning
Fuel
hoses
Inspection
from
and cleaning
the fuel
tank
a)
Pull the mains plug and let the unit cool down completely before cleaning,
adjusting or replacing accessories and when the unit is not in use.
b)
Wait until the rotating parts stop.
c)
Use only non-corrosive cleaning agents for cleaning the surfaces.
d)
Store the unit in a dry and cool place protected from moisture and direct
sunlight.
e)
Do not spray the unit with a stream of water or immerse it in water.
f)
Make sure that no water enters through the ventilation openings in the
casing.
EN
After
month or
Daily
20
operating
hours
x
x
x
1
Every
3
Every six
months or
months
50
or
working
working
hours
hours
x
Every 2 years
Every year
or
after
100
300
operating
hours
x
x
x