Battery Type
The ECO-N charge controllers do not provide an equalization charge, and therefore
are suitable for use with lead acid batteries with liquid electrolyte (vented battery) and
lead acid batteries with immobilized electrolyte (GEL or AGM type). In case of any
doubts consult your dealer.
Recommendations for Use
The controller warms up during normal operation.
The controller does not need any maintenance or service. Remove dust with a dry
tissue.
It is important that the battery gets fully charged frequently (at least weekly).
Otherwise the battery will permanently be damaged.
A battery can only be fully charged if not too much energy is drawn during the
charging process. Keep that in mind, especially when you install additional loads.
Display Functions in normal operation
The controller is equipped with 3 LEDs to display the operating status.
In normal operation, the controller shows the charging status, the battery SOC status
and the load output status.
Charge display
Controller connected to
battery, no sunlight
over longer period
(Green LED on)
Controller connected to
battery, day detected
(Green LED flashes)
No battery connected
(Green LED off)