Descargar Imprimir esta página

ARIETE 4146 X Vapor Deluxe Manual Del Usuario página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
FILLING THE BOILER TANK DURING USE
When there is no more water in the boiler (M), turn off the appliance, disconnect the plug from the electrical outlet and
proceed as follows:
press the button (A) to discharge the residual steam.
The safety cap (N) cannot be unscrewed until the boiler is pressurized, therefore wait a few seconds before opening the
cap and pour water into the boiler.
Add some more water, pouring the first amount slowly to prevent steam puffs.
Screw the safety cap (N) completely.
Plug in appliance.
Press the on/off switch (L).
Emptying and cleaning the inside of the boiler tank
ATTENTION: Clean the boiler at least once a month to remove all limescale residues that could jeopardize
the proper operation of the appliance.
ATTENTION: Switch the appliance off, unplug it and allow it to cool down before proceeding with the
boiler cleaning to prevent injuries.
Exhaust the residual pressure inside the boiler (M), by pressing the steam push button (A) on the gun (C) and directing
the jet into an appropriate container.
Screw the safety cap (N) slowly and remove it.
Fill the boiler (M) slowly with tap water to prevent any steam puff. Shake the appliance vigorously and turn it upside down
to empty. Repeat the above procedure several times.
ATTENTION: Never add limescale removers, vinegar or other perfumed substances into the boiler to prevent
the risk of damage of the unit and will immediately void the warranty.
Store the attachments using the apposite compartment (H) situated on the base of the appliance, then lift the appliance
using the rear lever (Fig. 9).
Place the attachments in the apposite spaces inside the compartment (H) (Fig. 10).
Position the appliance back on the compartment (H) by inserting the references on the appliance into the apposite front
holes on the compartment first and then pressing the rear part of the appliance downwards until it locks (Fig. 11).
Where appropriate, insert the floor brush (6) with the corresponding adapter (13) into the relevant hook situated in the
rear part of the appliance (Fig. 12).
PROBLEM
The nozzle
does not dispense steam
The nozzle
dispenses little steam
CLEANING AND MAINTENANCE
TROUBLESHOOTING...
CHECK
Steam ready light (I) on
Steam ready light (I) off
Steam ready light (I)
off – Water in the boiler (M)
Steam ready light (I) off
POSSIBLE CAUSES
Cold boiler tank
No water in the boiler tank
(M)
Malfunction
Cold boiler tank
Steam regulation dial (F)
set to minimum
- 17 -
EN
I T
POSSIBLE REMEDY
Wait for the steam ready
light (I) to switch off
Refill the tank, as descri-
bed in the paragraph
"INSTRUCTIONS FOR
USE"
Contact an ASSISTANCE
CENTRE
Wait for the boiler tank (M)
to heat up
Use the relevant dial (F) to
regulate the steam

Publicidad

loading