OPERATION
LED FUNCTIONS
See Figure 2, page 7.
MODE
BATTERY PACK
Without
Power
battery pack
Hot battery pack
Evaluate
Cold battery pack
Deeply discharged
Error
Error
• Try to repeat the conditions a second time by removing and reinstalling the battery pack. If the LED Error status repeats
a second time, try charging a different battery.
• If a different battery charges normally, dispose of the pack that received the Error (see your battery pack manual for
instructions).
• If a different battery also indicates Error, the charger should be replaced.
Charging
Charging
Full
Battery Full
Maintenance
Maintenance mode
Energy Save
Energy Save mode
Mode
(battery full)
NOTE: Maintenance information begins on page 6 after French and Spanish
This product has a 90-Day Satisfaction Guarantee Policy, as well as a
Three-year Limited Warranty. For Warranty and Policy details, please go to
www.RIDGID.com or call (toll free) 1-866-539-1710.
GREEN
LED
On
Off
Off
Flashing
On
Flashing
On
language sections. Illustrations start on page 7.
RED
LED
Off
Ready to charge battery pack.
When battery pack reaches cooled temperature, char-
ger begins charge mode.
When battery pack reaches warmed temperature,
Flashing
charger begins charge mode.
Charger conditions battery until normal voltage is
reached, then begins charge mode.
On
Battery pack or charger error.
Off
Battery is being charged.
Off
Battery pack is fully charged
Charging is complete; charger maintains fully charged
Off
state.
Battery pack is fully charged and charger is in Energy
Off
Save mode.
5 — English
ACTION