If it is found necessary to reverse the positions of the "Fully Open" and "Fully Closed" limit switches,
proceeds as follows.
1. Press the RESET button and, within 5 seconds, press simultaneously buttons 1 and 2.
2. After 5 seconds a double flash of the RESET, 1 and 2 Leds will signal that reversal has taken
place.
If for any reason it is not possible to complete the automatic limit switch setting procedure or if you
wish to set different stopping positions to those set automatically, then the manual limit switch setting
procedure can be performed (see attachment "H" fig. "2H").
The movement commands can be given from the motor keypad or by wire. The radio receiver is
inactive during the limit stop setting procedure.
1. Leds "1" and "2" flash simultaneously
2. Keep the RESET button pressed for 5 seconds
3. LED "1" lights up
4. Run the motor with the start button or with buttons "1" and "2" on the motor control panel until it
reaches the setting point for the first limit stop
5. Press the RESET button or the stop button (art. 5431, art. 5461)
6. LED "1" goes out and LED 2 lights up
7. Run the motor with the start button or with buttons "1" and "2" on the motor control panel until it
reaches the setting point for the second limit stop
8. Press the RESET button or the stop button (art. 5431, art. 5461)
9. LED "2" goes out
10. After a few seconds, LEDs "1" and "2" will flash together once to indicate that the setting
procedure has ended successfully
The motor control electronics will maintain the previous settings if a blackout occurs during the limit
stop setting procedure. Therefore, if you want to abort the limit stop setting procedure, just switch off the
power to reset the previously saved data.
After the limit stops have been set, you can also set up to two intermediate stopping points (see
attachment "I").
1. Run the system until reaching the position for the first intermediate stopping point
2. Press button "1" on the motor control panel for 5 seconds
3. The corresponding LED will flash to indicate that the control has been received
If you want to set a second intermediate stopping point (not mandatory)
4. Activate the system up to the position where you wish to set the second intermediate stopping
point
5. Press button "2" on the motor control panel for 5 seconds
6. The corresponding LED will flash to indicate that the control has been received
If the intermediate stopping points are set, when the system is run it will reach the first stopping point
in sequence. If you want to open or close the curtain completely, the control (whether from the button or from
the radio control) must be held for 4 seconds (the "RESET" Led on the motor control panel goes out for a
fraction of a second to signal that the command has been received).
By following the above-described procedure, you can change the intermediate stopping points at any
time without having to change the limit stops. To eliminate the intermediate stopping points, simultaneously
press buttons "1" and "2" on the motor control panel for 4 seconds (the corresponding LEDs will flash once to
indicate that the intermediate stopping points have been cancelled).
Setting the limit switches manually
Setting intermediate stopping points
4
Z258 rD
11

Publicidad

loading

Productos relacionados para Mottura POWER 571

Este manual también es adecuado para:

Power 571/1Power 571/2