Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60335-2-69.
L
sound pressure level ..................... 83.4 dB(A)
pA
K
uncertainty ....................................... 3 dB (A)
pA
L
sound power level ........................ 98.2 dB(A)
WA
K
uncertainty ....................................... 3 dB (A)
WA
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
Danger!
The electric power tool generates an electro-
magnetic fi eld during operation. Under certain
circumstances this fi eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
GB
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
Warning!
Always pull the power plug before making
adjustments to the equipment.
6. Assembly
Danger! Pull out the power plug before carry-
ing out any maintenance, resetting or assem-
bly work on the vacuum extraction system!
6.1 Assembling the base frame (Fig. 3 – 7)
- 19 -
www.sidirika-nikolaidi.gr
Unpack the vacuum extraction system and
check it for damage which may have occurred
in transit.
The machine has to be set up where it can
stand securely. All covers and safety devices
have to be properly fitted before the machine
is switched on.
Before you actuate the On/Off switch, make
sure that the debris bags are securely faste-
ned!
Check that the voltage on the rating plate is
the same as your supply voltage before you
connect the machine to the power supply.
Fit the wheels (10) on both sides of the
chassis (8) using the axle screw (21) and the
washer (22).
Tighten the axle screws (21).
Fasten the wheel caps (7) to the wheels (10).
As you do so, make sure that the plug-in con-
nector engages correctly.
Important! First screw the side plates (12)
and the strengthening plate (9) loosely to the
machine. This will simplify the assembly work
and will prevent tension in the chassis.
Use the long lock bolts (23) and nuts (25) to
fasten the two side plates (12) loosely to the
chassis (8). Check that the orientation is cor-
rect (see Fig. 4).
Place the strengthening plate (9) between the
side plates (12) and use the short lock bolts
(24) and nuts (25) to fasten it loosely (see Fig.
5).
Undo the two nuts (20) on both sides of the
plastic housing (13) (see Fig. 6).
Then guide the plastic housing (13) over
the side plates (12), insert the screws at the

Publicidad

loading

Este manual también es adecuado para:

43.041.56