Descargar Imprimir esta página

Mitsubishi Electric MXZ-2B20NA Manual De Instalación página 5

Acondicionadores de aire de tipo dividido
Ocultar thumbs Ver también para MXZ-2B20NA:

Publicidad

Idiomas disponibles

Idiomas disponibles

2. OUTDOOR UNIT INSTALLATION
2-1. CONNECTING
WIRES FOR OUTDOOR
UNIT
*
Be sure to use special circuits for room air conditioner.
*
Wiring work should be based on applicable technical standards.
*
Wiring connections should be made following the diagram.
*
Screws should be tightened so they won't loosen.
ELECTRICAL SPECIFICATIONS
OUTDOOR UNIT
MXZ-2B20NA
Power supply (V, PHASE, Hz)
208/230, 1, 60
Max. Fuse size (time delay) (A)
20
Min. Circuit Ampacity (A)
15
Fan motor (F.L.A)
0.96
Compressor
REA)
10.4
(L.R.A)
15
Contro! voltage
Indoor unit-Remote controller : (Wireless)
Indoor unit-Outdoor unit : DC12-24V
1) Remove the service panel.
2) Fix the conduit connector to conduit cover with
lock nut then
secure
it
against unit with screws.
3) Fix the conduit cover to the outdoor unit then secure it with screws.
4) Connect power supply cord and indoor/outdoor connecting wire to the ter-
minal block.
(Leave some slack in wires to allow easier servicing.)
Grounding terminal
Conduit
5) Close the service panel securely. Make sure that 3-2. PIPE CONNECTION
DBs
/ cover
is completed.
.
'
as
| S
Lock nut
Connector
Remark:
=
*
A disconnect switch should be required. Check the local code.
MPCOR UNTE]
INPOOR UN TEE
** Use aring tongue terminal in order to connect a ground wire to terminal.
erminal
bloc
erminal
bloc
AN
tS
Grounding
:
, | Grounding
terminal **
: A A Ai
terminal **
*
i
a
208/230 V AC
Disconnect
208/230 V AC
Disconnect
iphase 60 Hz
switch *
iphase 60 Hz
switch *
Grounding
Grounding
terminal **
terminal **
4
&
O
Oo
Terminal
SiS283
S1/S2S3
block 1
Terminal block
Terminal block,
UNITA
UNIT B
OUTDOOR UNIT
Pe
L
fe
Ground
rower SUPP
ea
VAC
| e
Connect wires to the matching numbers of terminals.
phase
ewires
2
¢
Be sure to attach each screw to its correspondent
terminal when securing the cord and/or the wire to the
terminal block.
CONNECTING WIRES AND CONNECTING GROUND WIRE
°
Use solid conductor AWG14
or stranded conductor AWG14.
*
Use double insulated copper wire with 600 V insulation.
°
Use copper conductors only.
Follow local electrical code.
POWER SUPPLY CABLE AND GROUND WIRE
°
Use solid or stranded conductor AWG 14.
°
Use copper conductors only.
*
Follow local electrical code.
Z\ WARNING:
Use the indoor/outdoor unit connecting wire that meets the Standards to connect the indoor and outdoor units and fix the wire to the terminal
block securely so that no external force is conveyed to the connecting section of the terminal block. An incomplete connection or fixing of the
wire could result in a fire.
For future servicing, give extra length to the connecting wires.

Publicidad

loading