Installation
CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns,
unplug the pump and allow time for it to cool after periods of extended use.
Recommended Installation For All Applications
1. Electrical wiring and protection must be in accordance with governing electrical codes.
2. Install proper PUMP (combination union and check valve), preferably just above the basin to allow easy
removal of the pump for cleaning or repair. If high head or below-cover installation is required, use 1-1/2" (DN40)
pipe, 2" (DN50) pipe.
3. All installations require a basin cover to prevent debris from falling into the basin and to prevent injury.
4. When a PUMP is installed, drill a 3/16" (5 mm) diameter hole in the discharge pipe even with the top of the
pump. NOTE: THE HOLE MUST ALSO BE BELOW THE BASIN COVER AND CLEANED PERIODICALLY.
(High Head unit see "Caution" on front page). Water stream will be visible from this hole when pump is operating.
5. Securely tape or clamp power cord to discharge pipe, clear of the float mechanism(s).
6. Use a discharge pipe equivalent in diameter to the pump's discharge.
7. Basin must be in accordance with governing codes and specifications.
8. Pump must be level and float mechanism(s) clear of sides of basin before starting pump.
9. Basin must be clean and free of debris after installation.
10. Gate valve, shut-off valve, or ball valve to be supplied by installer and installed according to any and all codes.
11. Locate float switches as shown in sketches. The best place for the "off" point is above the motor housing and
positioned 180°from the inlet. Never put "off" point below discharge on pump
12. Gas-tight seals are required to contain gases and odors.
13. Vent gases and odors to the atmosphere through vent pipe. Must comply with local codes but not required for
dewatering.
All installations must comply with all applicable electrical and plumbing codes, including, but not limited to,
National Electrical Code, local, regional, and/or state plumbing codes, etc. Not intended for use in hazardous
locations.
For Professional Technical Support call 1-844-242-2475