Kit Contents:
■ (1) Temperature Monitoring Control
■ (1) Thermocouple (muffl er clamp)
■ (1) Ground Wire
■ (1) Limit In Wire
■ (1) Limit Out Wire
■ (1) Splash Cover
■ (1) Service Kit Literature
Kit instructions are intended to be used
NOTICE
with the support of the proper service
manual.
In the event that the rear of the unit is not
accessible, refer to the owners manual
for removal and installation procedure.
Tools Needed:
■ Nut driver set
■ Inch Lb Torque Wrench
■ 5/16" socket, 1/4" socket
■ Work gloves
Purpose
To detect improper operation of the cooling unit by monitoring
the surface temperature of the boiler. In the event an abnormally
high temperature is detected, all heat source outputs to the
cooling unit will be disabled. This condition can be reset by an
authorized service center. Contact a center near you to schedule
an appointment.
2118 Series - Temperature Monitor Control (TMC)
8
17
12
4B
4A
4
14
13
Fig. 1
References
1. Shell
2. Insulation
3. Burner Box
4. Thermocouple (shown below)
5. Heater Tubes
6. Boiler
7. Flue Tube
8. Temp Monitoring Control (shown below)
9. Power Board Cover / 9A Screws
10. Power Board
11. Power Board
12. 15" Red Limit Out Wire (shown below)
13. 15" Blue Limit In Wire (shown below)
14. 7" Green Wire (shown below)
15. Power Board - Red 12 VDC
16. Power Board - Black Ground
17. Splash Cover
Procedures
To install the kit, complete the steps in the order presented on the
following pages.
The following procedure is to be
WARNING
!
performed by authorized service
ATTENTION
personnel only. Improper installation,
adjustment, alteration, service or
maintenance can cause injury or property
damage.
Shock hazard. Be sure AC and DC
electrical power to the refrigerator are
turned off.
637360
Service Kit

Publicidad

loading

Resumen de contenidos para Norcold 637360

  • Página 1 637360 Service Kit 2118 Series - Temperature Monitor Control (TMC) Fig. 1 References Kit Contents: 1. Shell ■ (1) Temperature Monitoring Control 2. Insulation ■ (1) Thermocouple (muffl er clamp) 3. Burner Box ■ (1) Ground Wire 4. Thermocouple (shown below) ■...
  • Página 2 1. Expose Boiler If you smell ammonia or see yellow chromate powder during the installation, DO NOT continue. Call Customer WARNING Service. ATTENTION Fiberglass insulation - keep away from eyes. Wear gloves for skin protection. To avoid burn, verify burner box (3) area is cool. 1.
  • Página 3 637360 Série 2118 - Commande de monitorage Serie 2118 - Control para monitorear de température temperatura L’ensemble contient : Contenido del juego: ■ (1) Commande de monitorage de température ■ (1) control para monitorear temperatura ■ (1) Thermocouple (bride de fi xation) ■...
  • Página 4 Références Referencias 1. Enveloppe 1. Cubierta 2. Isolant 2. Aislamiento 3. Boîtier de brûleur 3. Caja del quemador 4. Thermocouple (illustré ci-dessous) 4. Termopar (se muestra abajo) 5. Tuyaux de chauffage 5. Tubos del calefactor 6. Chaudière 6. Caldera 7. Tube d’évacuation 7.
  • Página 5 Exposer la chaudière Exponga la caldera Si, au cours de l’installation, une odeur Si huele amoníaco o ve polvo de WARNING AVERTISSEMENT WARNING AVERTISSEMENT ADVERTENCIA d’ammoniac est décelée ou de la cromato amarillo durante la instalación, ATTENTION ATTENTION ATTENTION ATTENTION ATTENTION poudre de chromate jaune est visible NO siga adelante.
  • Página 6 Brancher l’électricité Conexiones eléctricas WARNING : High voltage can cause servere injury and death. ONLY qualified RV service techincians are autorized to remove this cover. Do not allow leak detecting solutions to touch the electrical components. Many liquids are electrically conductive and can cause a shock hazard, electical shorts, and in some cases fire.