IMPORTANT: The control unit is equipped with the Autoset function to automatically set the main functioning values based on the type
of installation.
The AUTOSET function must be repeated at every function parameter change or upon change of automation conditions. See the AUTO
menu for further information.
Wire connections shown in Fig. 1/2 are described hereunder:
Terminal
Function
L-N-GND
Power supply
+ -
Output 24Vdc
+BAT-
Batteries
Terminal
Function
Power supply
L-N-GND
Power supply selec-
M4
tion
Output 24Vdc
+ 24V -
Batteries
+BAT-
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
7-8
Lock
SCA/
9-10
PHOTO TEST
11-12
24 Vdc
13
COM/ENC+
14
SWO1/ENC1
15
SWC1
16
SWO2/ENC2
17
SWC2
18
PHOT
19
PHOT C
20
STOP
21
OPEN
22
CLOSE
23
PED
24
Step-by-Step
25
COM/ENC+
26
ENC-
18
BRAINY 24-SW/BRAINY 24+ CONTROL UNIT
AUTOSET FUNCTION
WIRE DIAGRAM
SA.24V (BRAINY 24-SW)
Description
Mains input 100÷250Vac 50/60Hz
Controller BRAINY 24 power supply output 24 Vdc
Clamp input for connection of back-up batteries (accessory).
SAR.24V (BRAINY 24+)
Description
Power supply input (115V ± 10% or 230V ± 10%) selectable via terminal M4
WARNING: to use the central unit with 115V power supply, it is necessary to jumper this
terminal.
Controller BRAINY 24 power supply output 24 Vdc
Clamp input for connection of back-up batteries (accessory).
BRAINY 24-SW/BRAINY24+
Description
Connection, motor 1: 24VDC 5A max
Connection, motor 2: 24VDC 5A max
Connection, flashing light 24VDC 15W max.
Output, 12Vdc/10W power supply for electric lock (7:+12V, 8:0V)
Contact free from N.O. Voltage, may be configured as open gate indicator or photocell test.
For use as "Open gate indicator" the TEST1 and TEST2 logics must be OFF
For use as photocell test it is sufficient to activate one or both TEST logics and connect the
photocells as indicated in Fig.3.
Output, accessory power supply, 24VAC/0.5A max.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switch and all the command inlets or encoder power supply.
Motor 1 OPEN limit switch input (N.C. contact) or Motor 1 Encoder connection.
Motor 1 CLOSE limit switch input, (N.C. Contact)
Motor 2 OPEN limit switch input, (N.C. Contact) or Motor 2 Encoder connection.
Motor 2 CLOSE limit switch input, (N.C. Contact)
Input, photocell activated in both opening and closing phases
Input, photocell activated in closing phase only (Normally closed contact)
Input, STOP push-button (Normally closed contact)
Input, OPEN push-button (Normally open contact).
It is possible to connect a timer for opening in time slots.
Input, CLOSE push-button (Normally open contact)
Pedestrian button input (N.O. Contact), controls the motor 1 opening, see TPED parameter.
Input, step-by-step push button (Normally open contact)
Common for Limit switch and all the command inputs or encoder power supply.
Input for GND Encoder connection (see Fig.3).