Descargar Imprimir esta página

Beninca BRAINY 24-SW Manual Del Usuario página 22

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
Enabled or disables HOLD-TO-RUN function
On: HOLD-TO-RUN function.
The pressure of the OPENS/CLOSES button must be maintained throughout the entire
htr
manoeuvre. The opening of the STOP input stops the motor. All the safety inputs are
deactivated, except for the Limit switch inputs /SW01/SW02/SWC1/SWC2).
Off: Automatic/semiautomatic function
The operating mode with 1 or 2 motors is selected:
On: The motor operation is synchronised. This function must be used in the following
cases:
- for each single motor, connect it to M1: Terminals 1/2.
1mot
- for two synchronised motors (e.g. balancing doors), connect one motor to M1: ter-
minals 1/2 and the other to M2: terminals 3/4. Adjust the parameters related to motor
1, the M2 limit switch inputs are deactivated. TDMO and TDMC must be 0.
Off: For two non-synchronised motors, e.g. overlapping gate leaves, adjust TDMO
and TDMC on the desired values.
Enables or disables the programmable code transmitters.
IMPORTANT: The transmitters with programmable code can only be used in con-
junction with the Rolling Code HCS transmitters.
Cvar
On: Radio receiver enabled only for transmitters Rolling Code (ARC or HCS, the first
transmitter sets the operating mode).
Off: Receiver enabled for transmitters Rolling Code HCS and programmable (self-
learning and dip/switch).
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vdc.
Power is cut off to the electric lock output before each opening and closing opera-
mloc
tion.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vdc for the time set by the pa-
rameter TLOC.
Activates or deactivates the push in closing function. Only with logic SLD:ON
On: The last second of the manoeuvre in closing phase is carried out at normal speed
BB
(disabling slowing) to favour a better hook of the electric lock.
Off: Function disabled.
Enables or disables the second radio channel on terminals 29/30.
2ch
On: Exit 29/30 configured with function as second radio channel.
Off: Exit 29/30 takes on function of service light (see parameter TLS).
Enables or disables checking of photocells on PHOT input, active both in closing and
in opening.
TST1
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
See Fig.4 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables checking of photocells on PHOT inputs, active only in closing.
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
TST2
See Fig.4 - "PHOTO TEST".
Off: Checking of photocells disabled at each manoeuvre.
Enables or disables motors check.
TSTm
On: Check enabled. If the check has a negative result, no manoeuvre is commanded.
Off: Check disabled.
(Enables or disables remote radiotransmitters learning, as indicated in the paragraph
"Remote transmitters learning".
rem
On: Remote learning enabled.
Off: Remote learning not enabled.
22
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)

Publicidad

loading

Este manual también es adecuado para:

Brainy 24 +