Champion Operating Instructions & Parts Manual
Champion Two-Stage Air
Compressor Pumps
AIR COMPRESSOR OIL
SPECIFICATIONS
Compressors are factory filled with
CHAMPLUB hydrocarbon based recip
lubricant. This is an ISO 100 non-
detergent industrial lubricant with rust
and oxidation inhibitors specially
formulated for reciprocating
compressors. It is recommended this
E
compressor be maintained using this oil
N
for ambient temperatures above 32°F.
G
L
CHAMPLUB synthetic is a premium
I
grade diester based synthetic lubricant
S
providing excellent performance in high
H
temperature applications.
Do not mix oil
types, weights or brands.
fication of oil (white milky substance)
indicates unsafe accumulation of
moisture and may be evidence
compressor is oversized for
application. Failure to promptly
consult your local distributor, or
Champion Customer Service, can be
grounds to deny warranty."
NOTES:
1. Normal break-in period of Champion
air compressors is 25 hours.
2. For the first 100 hours of compressor
operation, a careful and regular
check of the oil level should be made.
Maintanin oil level at the full line.
CHANGING TO SYNTHETIC
LUBRICANT
(Applies to diester based synthetic
lubricant only).
If changing to synthetic lubricant, the
following steps must be completed.
1. Compressor must run for a 25 hour
break-in period using ChampLub
ISO 100 oil.
"Emulsi-
6
3Z180C and 3Z181C
2. Thoroughly drain existing oil from
crankcase.
3. Fill crankcase with a full charge of
synthetic lubricant.
4. Run compressor for 200 hours.
5. Stop compressor and thoroughtly
drain the synthetic lubricant.
6. Add a full charge of synthetic
lubricant.
7. Compressor now ready to run for
extended period before next lubricant
change.
LUBRICANT
DESCRIPTION
PART NUMBER
1 Quart Bottle
ChampLub Mineral
P13796A
Lubricant
1 Quart Bottle
P13929A
ChampLub Synthetic