AC/DC Voltage Measurement (U AC/DC)
Measurement Range UAC:
Measurement Range UDC:
Resolution:
Tolerance:
Internal resistance:
Overload protection:
UProtection Level
Measurement Range
10...1000 VDC
6 ... 625 VAC
Test voltage:
Test current:
Overload protection:
General
Display:
Battery type:
Current consumption:
Battery life:
Auto Power Off:
LCD backlight:
Fuse:
Data Memory:
IR/RS-232 interface:
Casing:
Overvoltage category:
Degree of contamination:
Type of protection IP:
Dimensions (LxBxH):
Weight:
Environmental Conditions
Reference temperature range:
Operation temperature range:
Height above sea level:
Subject to technical changes without notice!
10/2008
1 ... 600 VAC (Frequency f: 40 Hz ... 500 Hz)
1 ... ±600 VDC
1 V
±(3% rdg. +3 Digits)
660 kΩ
600 V AC/DC
Resolution
1 V
1 V
1 ... 1000 V DC
approx. 1 mA
1200 V AC/DC
3
/
digit LCD with bargraph
1
2
6 x 1,5 V, Type IEC LR6, Mignon
approx. 20 mA (standby)
for average use approx. 1 year
approx. 5 min
off after approx. 20 s
500 mA / 500 V - 6,3 x 32 mm
For input protection at Low-Ω function
up to 500 measurement values
9600 Baud, 1 start bit, 8 data bits,
Pair parity, 1 atop bit
Protection class II
CAT III / 600V or CAT II / 1000V towards ground
2
IP 50
235 x 105 x 68 mm
approx. 660 g incl. batteries
+17°C..22 ..27°C, max. 70% rel. humidity
0 °C...40 °C max. 80% relative humidity without
dewing
up to 2000 m
28
Tolerance
±(10% rdg. +5 Digits)
±(10% rdg. +5 Digits)
PAEB30872322

Publicidad

Tabla de contenido
loading

Tabla de contenido