5­ ELECTRICAL INSTALLATION
WARNING
Manufacturer recommends that this product be installed by a licensed and qualified electrician 
in accordance with all applicable national, state, provincial, and local electrical codes. As with all electrical 
appliances, under no circumstances should you attempt to install, repair or disassemble this water heater 
without first shutting off all power to the unit directly at the fuse or breaker box. Make sure to shut off all
breakers. SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
All wiring (wire gauge) and circuit protection (breakers) must comply with the U.S. National Electrical Code (NEC) 
in the USA, or the Canadian Electrical Code (CEC) in Canada. Failure to do so could result in property damage 
and/or personal injury, and void your warranty. Note: The Canadian Electrical Code generally requires that all 
supply wires and corresponding circuit protection used for domestic hot water heating and hydronic heating 
applications be sized to a minimum of 125% of the maximum current rating of the heater (see heater
specifications below for details).
Before installing this product, ensure that the home has sufficient electrical power available to handle the 
maximum amperage load of the applicable heater.
IMPORTANT NOTES:
8kW, 11kW and 13kW heaters require 1 set of wire and ground (see wiring diagram)
18kW heater requires 2 sets of wire and ground (see wiring diagram)
24kW and 27kW heaters require 3 sets of wire and ground (see wiring diagram)
36kW heater requires 4 sets of wire and ground (see wiring diagram)
Please see electrical specifications by heater input and wiring diagram on the next page for additional
electrical information.
Each set of wires must be connected to its own individual double pole breaker.
STEP 1: Take each wire pair and connect them to one breaker (see wiring diagram). Make sure that each breaker 
is connected with one black wire and one red wire
STEP 2: Using a suitable wire gauge that meets all applicable electrical codes for the size of the breakers used, 
run the correct sets of wire from the home's main breaker panel to the tankless water heater.
STEP 3: A separate ground conductor for each incoming circuit is required.
STEP 4: DOUBLE CHECK the electrical connections to make sure they are correct and that all wire connections 
are tight and secure. Also confirm that the correct breaker size and wire gauge has been used and confirm that 
the unit has been connected to a ground in accordance with applicable codes.
STEP 5: Confirm that all the air has been purged from the water lines prior to turning on power to the unit. Refer 
to STEP 2 in the plumbing installation section.
CAUTION
Ensure that you have made the correct connections. You must follow the wire connection as 
shown to ensure proper operation of the unit. If you mix up one set of wires with another, the unit will not 
operate correctly even though it turns on and otherwise appears to function properly.
The water heater is now installed and ready to use! Follow the General Operating Instructions to complete the 
setup. We highly recommend that this is done with the homeowner present.