COMMISSIONING AND USE
9.6
VENTILATION CONTROL UNIT
The control unit is used to manage hot air ventilation when fans are
installed. It is supplied together with the
also used when the
"Ventilated air ducting
l
Before using the control unit:
carefully read all the documentation accompanying
■
the product and the kit
make sure that all the indications provided by the
■
manufacturer and specified in the regulations are
observed
make sure that it is correctly installed and connected
■
to the appliance.
The instruments of the control unit and their related functions are il-
lustrated below.
1
2
3
4
Description
Status
(1)
DISPLAY
(2)
LED 1
LED 1 On
OFF
... when
pressed the
first time for
(3)
long
P1
... when
ON/OFF button
pressed the
second time
for long
... when
(4)
pressed the
P2
first time
DECREASE button
briefly
... when
(5)
pressed the
P3
first time
INCREASE button
briefly
... when
pressed the
first time
(6)
briefly
P4
MENU button
... when
pressed sub-
sequently
CS.STB.IST-1_EN_Rev.1.0_08-23
"Front ventilation
kit" and is
kit" is installed.
7
6
5
Fig. 29
Action
The control unit is switched
off.
Switches the control unit on.
Switches the control unit
off.
Modifies/decreases the
selected value.
Modifies/increases the
selected value.
Shows the current operating
mode on the display and the
relative LED lights up.
Cyclically selects the
operating modes signalled
on the display and by the
relative LED.
Description
Status
L2 On
(7)
L3 On
OPERATING MODE
L4 On
LED
L5 On
9.6.1 IGNITION
The control unit is switched (ON) and off (OFF) with the prolonged
pressing of button P1.
The (OFF) status is signalled by LED L1 switching on.
9.6.2 OPERATING MODES
MANUAL
With LED L2 (MAN) lit, the fan works at the set speed regardless of
the temperature read by the probe.
AUTOMATIC
With LED L3 (AUTO) lit, the fan activates at the set speed if the tem-
perature read by the probe is higher than the SET parameter setting.
PROPORTIONAL
With LED L4 (PROP) lit, the fan activates at the speed calculated in
the SET – (SET + DEL) parameter range if the temperature read by the
probe is greater than SET parameter setting.
9.6.3 FUNCTIONS
STAND-BY function
The function is active (parameter Stb=1).
With the device switched off (OFF), if the temperature read by the
temperature probe exceeds the value of parameter TSI, the device
automatically switches to the ON status (ON).
SAFETY function
The function is active (parameter SIC=1).
If the temperature exceeds the value of parameter TSI, with the fan
off and MANUAL mode (MAN) active, the device switches to PRO-
PORTIONAL mode (PROP) with a 10-second initial delay.
FAN SAFETY function
The function is not active (parameter SAF=0).
With the function active, if the temperature exceeds the value of pa-
rameter tSA, the fan is switched off (OFF).
ALARM function
The function is active (parameter Enb=1).
If the temperature exceeds the value of parameter TAL:
- the buzzer sounds which can be deactivated for 5 minutes by press-
ing any button
- after this time, if the alarm condition persists, the buzzer sounds
again.
EN
Action
MANUAL mode operation.
AUTOMATIC mode
operation.
PROPORTIONAL mode
operation.
Fan in function.
23