Care and Maintenance
• Clearance to Combustibles
Keep electrical cords, drapery, furniture and other combustibles at least 3 feet (0.9 m) from the front of the heater and
away from the sides.
• Cleaning Trim
Clean the trim using a soft cloth, slightly dampened with citrus oil based product and buff with a clean soft cloth.
DO NOT use brass polish or household cleaners as these products will damage the metal trim. Citrus oil based products
can be obtained at supermarkets or hardware stores.
• Periodic Cleaning Filter
Periodic cleaning/vacuuming of the filter is recommended. Make sure the unit is turned OFF and unplugged whenever you
are cleaning the heater.
Troubleshooting
1. Heater does not blow warm air.
2. Low air outlet speed and higher temperature.
Filter Cover
WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or rewiring of this unit
should be carried out by a licensed electrician in accordance with national and local codes.
If repairing or replacing any electrical component or wiring, the original wire routing, color coding and securing
locations must be followed.
WARNING: Electrical outlet wiring must comply with local building codes and other applicable regulations to
reduce the risk of fire, electrical shock and injury to persons.
WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a qualified service
technician to inspect the fireplace and replace any part of the electrical system.
WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire,
electrical shock or personal injury.
WARNING: During any service of this appliance, the power to the unit must be turned off. First turn the main
power switch to the OFF position. Then remove the electrical plug from the wall outlet.
Problem
Filter
1a. The ambient temperature is higher than the thermostat setting.
Adjust the setting higher.
1b. Unplug the unit from the wall outlet for 2 hours. After 2 hours plug
the unit back into wall outlet, and operate as normal.
1c. Check if the air inlet is blocked or the air filter is dirty and needs to
be cleaned.
1a. Check if the air inlet is blocked or the air filter is dirty and needs to
be cleaned.