connecting the wire
The terminal block is attached to the bottom of the power board, just under the plastic
control board housing. There are two wire connectors (C1 and C2) at the bottom of the
terminal block.
FRONT VIEW WITHOUT COVER
6. Bring the two 6 AWG wires to the connec-
tors, insert the leads, and secure them by
tightening the screws on the terminal block
using a flathead screwdriver. It does not
terminal
matter which wire (red or black) goes into
block
which circuit as long as they are both com-
ing from the same breaker.
7. Once the leads are
secured, tighten the
C1
Romex connector at
the 3/4" punchout on
the bottom of the unit.
Make sure to secure
tightly with enough
slack so the wire is not
weighing down the ter-
minal block.