9.4.
Lack of impulses on the flowmeter (AL3)
When the flowmeter does not receive impulses from the flowmeter, the display shows the following
alarm:
9.5.
Alarm for water filter system
When the water filter system needs maintenance, the display shows the following alarm:
This alarm appears when the maximum amount of liters (set in the technical programming) has
been reached and the filter needs to be renewed.
In order to switch off the alarm, access the user programming menu while the machine is in OFF-
mode.
Press
and introduce the password (6) (6) (6) (6) (6). Pass through the following displays until
reaching the display shown below. Press RESET. Then switch off the machine on the main switch and
switch it on again. This resets the counters.
9.6.
Maintenance Alarm
When the maximum amount of coffee produced has been reached, the display shows the following alarm:
This alarm appears when the maximum number of coffee, preset in the technical programming, has
been reached and the machine needs maintenance.
In order to switch off the alarm it is necessary to enter the user programming while the machine is
in OFF-mode.
58
Espresso Coffee MachineCompass MB by fiamma
(Translated from original language) ENGLISH