Rated Data - Lenze L-force E94AZMP0824 Instrucciones Para El Montaje

Filtro de red
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4
Technical data

Rated data

4.2
Rated data
Mains
3/PE AC
3/PE AC
3/PE AC
E94AZMP0824
E94AZMP2004
E94AZMP0824
 Temperature in the control cabinet
2)
For i700 mounting: mains connection at the bottom, output at the top
E94AZMP0824
E94AZMP2004
Thermal contact
E94AZMP0824
E94AZMP2004
Fan
E94AZMP0824
E94AZMP2004
46
Voltage
U
[V]
Lrated
230
400
500
Voltage
[V]
230/400/500
230/400/500
2)
400/500
Power loss
P
[W]
loss
200
350
Design
NC contact, 150 °C
Voltage
[V DC]
l
Voltage range
U
[V]
Lrated
180 − 0 % ... 264 + 0 %
320 − 0 % ... 440 + 0 %
400 − 0 % ... 550 + 0 %
Freq.
Current [A]
 max. +45° C
[Hz]
50/60
82/82/82
50/60
200/200/200
50/60
49/49
Inductance
L [mH]
0.25
0.10
max. switching voltage
U
[V AC]
Th
250
24
EDK94AZMP45 DE/EN/FR/ES/IT 7.0
Frequency range
f [Hz]
45 − 0 % ... 65 + 0 %
45 − 0 % ... 65 + 0 %
45 − 0 % ... 65 + 0 %
Current [A]
Number
of phases
 max. +55° C
61/61/61
3
150/150/150
3
30.6/30.6
3
Voltage drop
DU [V]
6.4
6.3
max. switching current
I
[A]
Th
2.5
Current
[A]
0.3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

L-force e94azmp2004

Tabla de contenido