Cable
from
Residence
White
Wire
i
(Neutral)
/""-7
Black
_
W,res-
i_id_
_
_Red
"_ ......
L------------_
l
__'_W
ct,on
(or Bare Copper)
.....
Conduit
Wire
Cable
from
Connector
Range
(or CSA listed)
Figure 5
3-Wire (Grounded
Neutral) Electrical
System
(Example: Junction
Box)
Where local codes DO NOT permit connecting
the
appliance-grounding
conductor
to the neutral
(white)
wire, or if connecting
to 4-wire
electrical
system (see Figure 6):
1.
Disconnect the power supply.
2.
Separate the green (or bare copper) and white
appliance cable wires.
3.
In the circuit breaker, fuse box or junction box:
connect appliance and residence cable wires as
shown in figure 6.
Cable from
Green
Residence
(or Bare Copper)
Wire
i
Junction
Box
White
Wire
(Neutral)
Wires
Countertop
Preparation
_,
The cooktop sides of the
fit over the cutout
range
edge of your countertop.
• If you have a square finish (flat) countertop,
no countertop preparation is required. Cooktop
sides lay directly on edge of countertop.
• Formed front-edged
countertops
must have
molded edge shaved flat 3/4" (1.9 cm) from each
front corner of opening (Figure 7).
• Tile countertops
may need trim cut back 3/
4"(1.9 cm) from each front corner and/or rounded
edge flattened (Figure 7).
Min.
Cutout
_/Width
311/J_ /
(81 cm)
J
Formed
or tile
countertop
(1.9 cm)
trimmed
_A" (1.9
cm)
back
at
I
front
corners
of countertop
opening.
Figure 7
If the existing
cutout
width
is greater
than
30-1/16"
(76,4 cm), reduce the 3A,, (1.9 cm)
dimension.
Countertop
must be level, Place a level on the
countertop,
first side to side, then front to back. If
the countertop
is not level, the range will not be
level. The oven must be level for satisfactory
baking results. Cooktop sides of range fit over
edges of countertop opening.
Green
(or Bare Copper)
White
Wire
Wire
(Neutral)
...........
U.L.-listed
Cable from
Conduit
Appliance
Connector
(or CSA listed)
Figure 6 - 4-Wire Electrical
System
(Example: Junction Box)
__
For existing cutout
29"
Q
width
of
(73.7 cm) (Figure 8):
2 3/16"
2 3/16"
(5.56 cm)
You
must
also
clear
(5 56cm)
2 3/16"
(5.56
cm) of
(3.2 cm)
Cabinet
Construction
(_)_
To eliminate the risk of cabinet
burns or fire do not have cabinet storage space
above the range. If there is cabinet storage space
above range, reduce risk by installing a range hood
that projects horizontally a minimum of 5" (12.7
cm) beyond the bottom of the cabinet.
(3.2 cm)
I
30'
(76.2 cm)
311/2"
(80 cm)
_Formed
or tile countertop
___
trimmed
11/4 '' (3.2 cm) back at
Figure 8
7