2. Position the device on the assembly surface so the blanking plugs are on the
side of the mounting panel.
3. Slide the cylinder head screws (WS 4) into the through holes (6) and the
mounting plate (11).
Tightening torque: 6 Nm
6.4.2 Fastening with a mounting kit for mounting plate
14
14
13
13
12
12
Fig. 2: Mounting kit for mounting plate assembly
12 Mounting panel
14 Cylinder head screws
A mounting kit R414002582 is needed to assemble the device on a mounting
plate. The mounting kit for the mounting plate contains:
• 2x mounting panels (12)
• 2x toothed rings (13)
• 2x cylinder head screws (WS 4) (14), tightening torque: 6 Nm
1. Refer to the dimensional drawing for the hole spacing. See
sioned
drawing.
2. Assemble the mounting kit for the mounting plate as shown. See g Fig. 2.
The mounting panels (12) catch in the recesses and can thus be aligned in
three directions at right angles to the device.
3. Fasten a single device with two mounting panels or stacked devices with at
least four mounting panels to the mounting plate.
6.5 Assembling on a rail
15
15
Fig. 3: Mounting kit for rail assembly
15 Mounting plate
To assemble the device on a rail, you will need the TH35-7.5 rail mounting kit
R414002583. The mounting kit includes:
• 1x mounting plate (15)
• 1x cylinder head screw (WS 4) (16), tightening torque: 1 Nm
1. Assemble the mounting kit as shown.
The mounting panel (15) catches in the recesses and can thus be aligned in
three directions at right angles to the device.
2. Fasten a single device with one mounting panel or stacked devices with at
least two mounting panels to the rail.
AVENTICS™ ED02 | R414002573-BAL-001-AG | English
14
14
13
13
12
12
00125294
13 toothed ring
g 14.2 Dimen-
16
16
00125296
16 Cylinder head screw
6.6 Connecting pneumatics
Danger caused by escaping compressed air!
Device is operating under pressure. If the alternative inlet connection (8) is
opened, the blanking screw (9) may be forced out by the escaping compressed
air and cause injuries or damage.
1. Always use your personal protective clothing or at least safety goggles.
2. Only connect an additional supply pressure connection in a pressure-free
state.
3. Never open the blanking screw while the device is in operation.
The inside diameter of the supply line must be at least 4 mm (6 mm with four
stacked devices) to attain the air flow rate stipulated in the specifications.
To avoid changing the dynamics of the ED02 pressure regulator, we
recommend using push-in fittings.
To connect push-in fittings, slide the tubing up to the stop in the push-in fitting
and gently tug to see if the tubing is tightly inserted.
6.6.1 Pressure regulators for positive pressure range (e.g. 0 to 2 bar,
0 to 6 bar, 0 to 10 bar)
See
g Fig. 7
1. Connect the supply line at inlet connection 1 (1) or at the alternative inlet con-
nection (8).
You can increase the air flow rate in stacked devices by connecting the
supply line to inlet connection 1 (1) and to the alternative inlet con-
nection (8).
2. Close the unused inlet connection with a blanking screw (WS 2.5), if neces-
sary.
Tightening torque: 1.2 Nm
3. Connect the outlet line at outlet connection 2 (2).
6.6.2 Pressure regulators for –1 to +1 bar
See
g Fig. 7
1. Connect the supply line at inlet connection 1 (1) or at the alternative inlet con-
nection (8).
2. Close the unused inlet connection with a blanking screw (WS 2.5), if neces-
sary.
3. Connect the outlet line at outlet connection 2 (2).
4. Remove the silencer from exhaust 3 (3) and connect the vacuum line at vac-
uum connection 3 (3).
6.6.3 Pressure regulators for 0 to –1 bar
See
g Fig. 7
Malfunction due to contaminated air at the exhaust!
Contaminated air sucked in via exhaust 3 (3) will damage the device.
1. Observe the specifications for compressed air quality listed in the technical
data.
2. Connect an additional filter at exhaust 3, if necessary.
1. Connect the vacuum line at vacuum connection 1 (1) or at the alternative in-
let connection (8).
2. Close the unused connection (1 or 8) with a blanking screw (WS 2.5), if neces-
sary.
3. Connect the outlet line at outlet connection 2 (2).
4. Connect the filter at exhaust 3 (3).
6.7 Connecting the supply voltage and set point
To operate the ED02 pressure regulator, you must supply the device with com-
pressed air, connect the 24 V DC supply voltage, and control the device with a set
point.
In all devices, the actual value (–) and set point (–) are always at 0 V
(pin 3).
CAUTION
NOTICE
18