STATUS INDICATOR
EN
Power Button LED Indicator
Solid green
Flashing green (1Hz) for
1 minute, then shuts off
Solid red for 1 min, then
shuts off
Flashing red quickly
(2Hz) for 1 minute, then
shuts off
Flashing red slowly
(1Hz) for 1 minute, then
shuts off
OVER TEMPERATURE PROTECTION
If the battery or power inverter temperature exceeds 70°C
during operation, the power button LED indicator will glow
solid red for 1 minute, and then the temperature-protec-
tion circuit will shut off the power inverter to protect from
overheating damage. Allow the battery and the power
inverter to cool until the temperature drop below 67°C
before restarting.
LOW BATTERY PACK CHARGE PROTECTION
When the batter pack charge reaches a low level, the
power button LED indicator will flash for 1 minute and
then the power inverter will automatically shut down.
Charge the battery pack.
OVERLOAD OR SHORT CIRCUIT PROTECTION
When the connected AC device draws more than the rated
power of the port, the power button LED indicator will
flash red quickly for 1 minute, and then the power inverter
will automatically shut down.
Disconnect the AC device.
6
56 VOLT POWER INVERTER — PAD1800E
Working Condition
Standby
The connected USB device(s)
draw(s) no more than 2W and
the connected AC device draws
less than 5W.
Powering connected devices
Low battery voltage
The power inverter or battery
pack is overheated.
The power inverter may be
overloaded or short circuited.
Other electronics error.
To connect external devices:
1. Install a battery pack onto the power inverter.
2. Press the power button to turn on the power
inverter. The LED in the power button will glow solid
green, which means the power inverter is ready for
supplying power.
3. Connect devices into the power inverter's USB ports
and/or 220-240V AC output port. The inverter will
begin powering the devices automatically.
4. When the power inverter is not in use, disconnect
devices from the power inverter, then press the
power button to turn off the power inverter.
5. Remove the battery pack from the power inverter.
Action
Normal operation. The power
inverter will shut off automatically
in 2 hours if there is no device
connected.
The power inverter could still power
the devices but will shut off auto-
matically in 2 hours.
If this happens, turn the power
inverter back on.
Normal operation.
Charge the battery. See "LOW BAT-
TERY PACK CHARGE PROTECTION"
below.
Allow the unit to cool down, then
restart the inverter. See "OVER TEM-
PERATURE PROTECTION" below.
Disconnect device from the AC out-
put port, see "OVERLOAD OR SHORT
CIRCUIT PROTECTION" below.
Disconnect your device and
reconnect it again, if the same
fault reoccurs, please contact EGO
customer service center.

Publicidad