Descargar Imprimir esta página

Cleco CellClutch CLBA Serie Manual De Instrucciones página 13

Herramienta ec sin cable

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8.3
Emissions
Order No.
CLBA083-(...)
CLBAW083-(...)
CLBA123-(...)
CLBAW123-(...)
CLBA203-(...)
CLBAW203-(...)
CLBA303-(...)
CLBAW303-(...)
CLBA403-(...)
CLBAW403-(...)
CLBA653-(...)
CLBAW653-(...)
CLBP04Q-(...)
CLBPW04Q-(...)
CLBP08Q-(...)
CLBPW08Q-(...)
CLBP12Q-(...)
CLBPW12Q-(...)
8.4
Ambient conditions
Features
Operation site
Working temperature
Storage temperature
Type of cooling
Relative humidity
Working height
Degree of protection EN 60529
9
Troubleshooting
Problem
Tool does not start.
Tool not recognized.
Tool does not start with counter-
clockwise rotation activated.
Apex Tool Group
Sound Level
Sound Level
Free Speed
Uncertainty
ISO 15744
[dB(A)]
<70
<70
<70
<70
<70
<70
<70
<70
<70
Data
Indoors
0 °C – 40 °C
-25 °C – 65 °C
Convection (self-cooling)
10 % – 90 %, no condensation
Up to 3000 m (9,843 ft) above sea level
IP40
Possible cause
No speed programmed.
Tool temperature is too high.
Battery voltage is too low.
Software is incorrect.
Connection to laptop/PC is not
available.
Tool is defective.
With counterclockwise rotation,
parameter for Speed is 0 rpm.
P2547BA | REV F l 2023-11
Vibration Level
No Load
ISO 28927-2
[m/s²]
3
<2.5
3
<2.5
3
<2.5
3
<2.5
3
<2.5
3
<2.5
3
<2.5
3
<2.5
3
<2.5
Measure
► Program speed for all active stages.
► Cool down the tool.
► Change battery.
► Check CLPC100 laptop/PC software.
► Check USB cable.
► Check PC driver.
► Change tool.
► Program the speed for counterclockwise rota-
tion: In the CLPC100 PC software, set the
Speed and Rotation in the Forward and Re-
verse Application Settings.
1
EN
Vibration Level
Uncertainty
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
13

Publicidad

loading