EN
Problem
Tool starts in tightening direction,
but not in counterclockwise rota-
tion.
Tool shuts off prematurely.
Tool does not change speed.
Status/work light is disabled.
No-load speed not reached.
Expected number of test rundowns
is not achieved with one charge of
the battery.
Status light flashes, see chapter
5.1 Status Indication, page 9.
14
Possible cause
No speed programmed for
counterclockwise rotation.
Operator releases start trigger
before the controller stops the
tool.
The fastening time exceeds
the standard time of 10 sec-
onds.
Tool exceeds the angle set-
point.
Speed is the same in all
stages.
Disabled by parameter setting. ► Parameterize the work light: In the CLPC100
Battery voltage is too low.
Battery is not fully charged.
High torque is needed during a
fastening sequence, e.g. for
coated fastenings.
Battery is at end of life.
Encoder is defective.
Tool temperature is too high.
Battery voltage is too low.
Warning that the next mainte-
nance is due.
P2547BA | REV F l 2023-11
Measure
► Program the counterclockwise rotation: In the
CLPC100 PC software, set the Rotation to
Reverse in the Forward and Reverse Applica-
tion Settings and parameterize the Speed.
If Forward is selected for
Enabled Direction, the
counterclockwise rotation of the
reverse switch has no function.
► Make sure that the operator keeps the start
trigger pressed throughout the entire se-
quence.
► Increase the fastening time.
► Check the fastening sequence to ensure that
the torque shutoff value and/or angle setpoint
are correct. Adjust as necessary.
► Check whether the fastening joint has
changed significantly.
► Make sure that the speed in the stages is cor-
rect.
PC software, select Bright or Dim for Work
Light.
► Parameterize the status light: In the CLPC100
PC software, select Bright or Dim for Status
Light.
► Use a fully charged battery.
► Use a fully charged battery.
If a high torque is needed for a longer period, e.g.
for several turns, the number of rundowns that can
be achieved with one battery charge will be signifi-
cantly reduces.
After 800 charging cycles, the capacity is reduced
to approx. 60%.
► Use new battery.
► Press start switch. If the status light continues
to flash, send the tool to a Sales & Service
Center for repair.
► Allow the tool to cool down. The current run-
down can be terminated, but a new one can-
not be started.
► Change battery.
► Send the tool to a Sales & Service Center for
maintenance.
Apex Tool Group