EN
!
Always ensure that the machine is switched off prior to any maintenance.
To clean the floor tool, remove securing-pin and pull-free from the holder.
Rinse the floor tool assembly with clean water and refit.
Periodically the floor tool blades should be examined and checked for wear and damage.
The blade removal is easy. Simply start by removing the four retaining pins, turn the
floor tool over and separate the blade carrier from the body. Peel away the blades from their locating lugs
and examine or renew as required. Replacement is a reversal of the removal process.
Floor Tool Overview
1. Retaining pins x 4
2. Rear blade
3. Blade carrier
4. Front blade (slotted)
5. Floor tool main body
Note: The blades are designed to be
reversible, thus extending their useful
working life.
Floor Tool Blades
1
2
3
4
5
57