Usage
Open the case and remove the battery activation strip. Self-testing will start for 30 seconds.
When the sensor is in operation, if it is
triggered more than twice within 3 minutes,
it switches to standby mode to save power.
If no movement is detected within the next
Connect Button
3 minutes, the sensor goes back to working
mode.
Register in the control panel
Type your password followed by the Connection button " " on the control panel to enter the
Connection Mode. Press the connect button at the back of the motion sensor or trigger the
sensor (by moving in front of it).
Installation
Avoid mounting the detector close to windows, air conditioner, heater, refrigerator, oven,
sunshine and places where the temperature changes fast or where the air stream flows
frequently.
If two detectors are installed in the same detection scope, adjust the location to avoid
interferences and false alarms.
Top
Fix the bracket on the wall with screws
and attach the detector to the bracket.
Adjust the bracket to change the
2.2 m
detection distance and angle. It is
recommended to mount the detector
2,2 m from the ground.
Ground
Bottom
The detector is more sensitive to
Side view
Top view
cross
movements
than
vertical
movements.
24