SOFTWARE INTERFACE
Appears when the hopper is not properly housed in its seat.
Hopper OUT
Appears when the grinders need to be replaced.
Grinder Alarm
Appears when the inverter temperature exceeds 60 degrees; the system is "paused" until
the inverter temperature falls below 52 degrees.
Inverter Temp.
Appears when the motor's critical temperature limit is exceeded, set in point 8.4 pg 46.
The system is "paused" for a period of 12 minutes+6 minutes.
Motor. Temp.
Appears when the motor temperature alarm set in point 8.4 pg 46 remains active for longer
than 18 minutes.
Motor Error
Appears when the motor's alert temperature limit set is exceeded, set in point 8.4 pg 46.
Motor Temp.
Appears when the grinder operates without grinding for more than 31 seconds.
No-load rotor
Appears when the motor is unable to turn the rotating grinder holder for more than 1.4
seconds.
Locked rotor
Appears when the display board can no longer communicate with the inverter board.
Comm. Error
Appears when there are errors on the inverter board connections.
Phase alarm
Appears when the inverter board detects a supply voltage higher than the pre-set limit
for correct machine operation.*
Overvoltage
Appears when the inverter board detects a supply voltage lower than the pre-set limit
for correct machine operation. **
Undervoltage
* AC 220V-230V: overvoltage 250V
AC 110V-120V: overvoltage 137V
50
** AC 220V-230V: undervoltage 190V
AC 110V-120V: undervoltage 91V