Gallagher 3E3115 Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
2. Func onal se ngs
Switch
Se ng
1
Relay 1
2
Relay 2
3
Relay 3
4
Fence alarms
5
Unused
6
Pulse monitoring
7
External inputs
ac vate
8
External inputs
ac va on mode
Se ng relay 1,2,3
In a standard installa on, relay 1 will be connected to a strobe light and relay 2 will
be connected to a siren. Relay 3 is exclusively used for alarms associated with the
external inputs.
The relays can be op onally med or latched. When med is selected, the ALARM
TIME determines how long the relay is turned on for. Refer to Alarm Time/ Delay
Time (p. 10) for further details. When latched is selected, the relays stay on un l the
reset bu on is pressed.
Fence alarms
In both modes of installa on (i-Series or standard), the alarm system can be set
to toggle only its relays under local se ngs (default) or have all connected alarm
systems act upon the alarms when set to global.
Pulse monitoring
This sets the alarm delay me when opera ng in i-Series mode. The alarm can be set
to trigger from either one pulse missed (default) or a er 15 seconds .
In standard mode the alarm can be set to trigger a er 7 seconds (default) or a er 15
seconds. Refer to Alarm Time/ Delay Time (p. 10) for further details.
When in standard mode the delay me can be set by the delay me trimpot.
8
Gallagher 3E3115 Alarm System User Manual
OFF (Default)
Latched
Timed
Latched
Local
One pulse missed
(i-Series mode)
7 seconds
(Standard mode)
Relay 3 only
Switch input
ON
Timed
Latched
Timed
Global
15 seconds (i-Series and
Standard mode
All relays
Security (balanced) inputs

Publicidad

Tabla de contenido
loading

Tabla de contenido