Descargar Imprimir esta página

Emerson AVENTICS AF2 Descripción De Sistema página 15

Sensor de caudal
Ocultar thumbs Ver también para AVENTICS AF2:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Q2 Menu
Function
Mode
SetPoint 1
SetPoint 2
Polarity
Simulate
DriverType
Fig. 13
Q2 Menu
Function
Mode
High
Low
MaxFreq
MinFreq
SimFreq
DriverType
Fig. 14
Q2 Menu
Function
Mode
Valency
Width
DriverType
Fig. 15
AVENTICS™ AF2 | R412028957-BAL-001-AB | English
Switch
Frequency
Pulse
Analog
abort
store
Switch Hyst Volumetric Flowrate
Switch Hyst Temperature
Switch Hyst Pressure
Switch Window Temperature
Switch Window Pressure
Switch Window Volumetric Flowrate
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
NormallyOpen
NormallyClosed
abort
store
Normal
Active
Inactive
abort
store
DRV
PNP
NPN
abort
store
Switch
Frequency
Pulse
Analog
abort
store
Vol Flow Rate
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
Off
10KHZ
1KHZ
100KHZ
abort
store
DRV
PNP
NPN
abort
store
Switch
Frequency
Pulse
Analog
abort
store
Volume
Energy
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
DRV
PNP
NPN
abort
store
Q2 Menu
Function
Mode
High
Low
Polarity
Fail
Simulate
Fig. 16
Qa Menu
The Qa menu contains the settings for the analog output.
Objective
Submenu
Assign measurement param-
Mode
eters to the current output
Assign the full scale value
High
Assign the measurement
Low
range start value
Set the inversion of the cur-
Polarity
rent output
Set the behavior of the cur-
Fail
rent output if a failure occurs
on the product
Set a predefined current
Simulate
value
Qa Menu
Mode
High
Low
Polarity
Fail
Simulate
Fig. 17
Switch
Frequency
Pulse
Analog
abort
store
4 ... 20 mA Volumetric Flow Range
4 ... 20 mA Temperature
4 ... 20 mA Pressure
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
Normal
Inverted
abort
store
3.5 mA
21.5 mA
abort
store
SimOff
3.5 mA
3.8 mA
4.0 mA
10.0 mA
12.0 mA
18.0 mA
20.0 mA
20.5 mA
21.5 mA
abort
store
Option
Assign measurement param-
eters such as flow, tempera-
ture, or pressure to the cur-
rent output
Set the full scale value to
20 mA
Set the measurement range
start value to 4 mA
Set the inversion of the cur-
rent output
Set the behavior of the cur-
rent output if a failure occurs
on the product
Set a predefined current value
4 ... 20 mA Volumetric Flow Range
4 ... 20 mA Temperature
4 ... 20 mA Pressure
abort
store
## # (unit)
abort
store
## # (unit)
abort
store
Normal
Inverted
abort
store
3.5 mA
21.5 mA
abort
store
SimOff
3.5 mA
3.8 mA
4.0 mA
10.0 mA
12.0 mA
18.0 mA
20.0 mA
20.5 mA
21.5 mA
abort
store
15

Publicidad

loading