Descargar Imprimir esta página

Diamond G77/TF7-N Instrucciones Para La Instalación, El Uso Y El Mantenimiento página 24

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.
For units with electric oven only
Electrical connection should be performed in compliance with the CEI regulations, only by authorised and competent
personnel. In the first instance, examine the data shown on the technical data table of this manual, on the label and on the
electrical diagram.
The envisaged connection is of the fixed type. The position of the terminal box, accessible by removing the left side, is
explained, for each model, on the present manual and on the oven base itself.
IMPORTANT: Ahead of each unit it is necessary to install an omnipolar main breaker, having a spacing among contacts of
at least 3mm; example:
- manual breaker of appropriate capacity, complete with fuse valves
- automatic breaker with respective magnetothermal relays.
4.1
EARTHING
It is essential to earth the unit.
To this purpose, it is necessary to connect to an efficient earthing system the terminals marked with the symbols (
on the line-receiving terminal box. The earthing system should comply with the law in force.
SPECIFIC WARNINGS
The electrical safety of this unit is assured only when it is correctly connected to an efficient earthing system as stated in
the electrical safety regulations in force; the Manufacturer declines any responsibility for the non-compliance with these
safety regulations.
It is necessary to verify this fundamental safety requisite and, in case of doubt, ask for an accurate testing of the system by
professionally qualified personnel.
The Manufacturer cannot be deemed responsible for any damages caused by the lack of unit earthing.
ATTENTION: NEVER INTERRUPT THE EARTH WIRE (Yellow-Green)
4.2
POWER SUPPLY CABLE
The unit is supplied fitted for the following voltages: 1N AC 220...240V 50Hz.
The flexible cable for power supply connection should not have characteristics lower than the rubber insulation type H07RN-
F. The cable should be inserted through the cable clasp and firmly fastened. Furthermore, the supply voltage with the unit
functioning should not go outside the value of the nominal tension ±10%.
4.3
EQUIPOTENTIAL
The unit should be included within an equipotential system whose efficiency must be tested according to the law in force.
The screw marked with the label "Equipotential" is located near the terminal box on the base.
4.4
ELECTRICAL CABLE CONNECTION
Gas units with electrical oven are supplied fitted to function at a voltage of 1N AC 220...240V 50 Hz; to carry out the electrical
connection it is necessary to:
- disassemble the left side
- connect the supply cable to the terminal box in accordance with the main supply voltage, following the electrical diagram.
The adhesive label is located near the terminal box.
ELECTRICAL CONNECTION
- 23 -
) placed
GB

Publicidad

loading