CAUTION: The wheel base can support a maximum of five batteries. Therefore,
the battery groups will have a maximum of 5 units, the inverter will be installed on
one of the groups.
CAUTION: The maximum battery limit is 15 units.
4.5 Power on
CAUTION: Double check all the power cable and communication cable.
-
Turn on all battery modules by pushing the switch to ON:
-
The battery that is connected to the inverter through the CAN port is the MASTER,
the others are slaves (1 MASTER battery can be configured with a maximum of 4
slave batteries):
Press the SW button of the inverter to turn on, all the LED lights of the batteries
will turn on sequentially from the main battery
NOTE: After the battery module powered on, the soft-start function takes 3s to
active. After soft-starts battery ready to output high power.
NOTE: during expansion of batteries or replacement, when parallel different
SOC/voltage of module together, please maintain the system in idle for ≥15min or
till the SOC LED becomes similarly (≤1 dot different) before normal operation.
4.6 Power off
1. Turn off external power source.
2. Turn off the power switch of batteries.
35