9. Technical specifications
Test currents
Resistance ranges
Output voltage
Measurement principle
Continuous operation time : At 200 A this equipment may be used continuously
Thermal protection
Basic accuracy
Advanced features
: 1 mA, 10 mA, 100 mA, 1 A, 10 A, 200 A.
Each current may be continuously adjustable from
0 to 100%
:
Currents
Range
200 A
0-199.9 µΩ
200 A
0-1999 µΩ
10 A
0-1999 µΩ
10 A
0-19.999 mΩ 1 µΩ
1 A
0-19.99 mΩ
1 A
0-199.99 mΩ 10 µΩ
100 mA
0-199.9 mΩ
100 mA
0-1999.9 mΩ 100 µΩ
10 mA
0-1999 mΩ
10 mA
0-19.999 Ω
1 mA
0-19.99 Ω
1 mA
0-199.99 Ω
For each test current, ranges are automatically selected for
optimal reading.
: Up to 10 Vd.c. @ 1 A (open circuit).
: Four-terminal, Kelvin-type.
for aprox. 3 minutes before the thermal protection
activates.
At 10 A or less, there is not a limited time for
continuous operation.
: Protects all sensitive components, avoiding any
damage due to overheating.
: R < 0,5 mΩ:
± (0,50 % of reading + 0,10 % of range).
R ≥ 0,5 mΩ:
± (0,20 % of reading + 0,05 % of range).
: Digital direct reading of very low resistances in the
alphanumerical display, with up to 4½ digits. Very
fast and accurate measurements.
17
Resolution
0,1 µΩ
1 µΩ
1 µΩ
10 µΩ
100 µΩ
1 mΩ
1 mΩ
10 mΩ