Descargar Imprimir esta página

Glow Fire Inside 106 Instrucciones De Montaje página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Hard Wiring Installation
TURN OFF THE APPLIANCE COMPLETELY AND LET COOL BEFORE SERVICING. ONLY A
PERSON SHOULD SERVICE AND REPAIR THIS ELECTRIC APPLIANCE.
HARD WIRING CONNECTION
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire
the appliance directly to the house hold wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired.
Fig 5-1
A.
Remove the cover plate from the right side
bottom of the appliance by removing the three
5-2
screws, as shown above. Fig 5-1
C.
Take the new cover plate, supplied in the hardware bag. Punch out the 7/8" (22.2mm) hole and install
a box connector through, into the junction box. Snap the box connector clamp onto the supply wires.
D.
Using the wire connectors, connect the ground green wires (G), the common white wires (N)
together, then the hot black wires (L) and then the refer to Fig 5-3
E.
Reinstall the cover plate using the three screws, as shown in Figure 1.
Fig 5-3
Glow Fire GmbH, James-Franck-Straße 23, 12489 Berlin
WARNING
QUALIFIED SERVICE
B.
Remove the wire connectors from the power
cord. The power cord may be discarded. Fig
Fig 5-2