Startup

5.1

Check connections

Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the connec-
tions carefully.
5.2

Turning on the system

Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no haz-
ards could result from these situa-
tions.
6

Versions (indicated on part label)

Supply voltage: 1 = DC 24 V
BTL5-S102B-M0450-P-(SA244)-S32
Nom. length (4digits):
B: Suitable for loop feedback / real-time
Resolution: 2 = 5 µm
Code: 24 bit 0 = binary, rising
25 bit 6 = binary, rising
6.1

Included in shipment

Transducer with condensed guide
Mounting brackets
5.3

Check output values

After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the magnet in manual mode. If
values other * than those present
before the replacement or repair are
found, a correction should be made.
* Transducers are subject to modifi-
cation or manufacturing tolerances.
5.4

Check functionality

The functionality of the transducer
system and all its associated com-
ponents should be regularly
checked and recorded.
Electr. connection, S32: with connector, 8 pin
Special version (if available),
SA244: low lag error, suitable for highly dynamic applications
Profile form factor
M = metric in mm
3 = 10 µm
1 = Gray, rising
2 = binary, falling
3 = Gray, falling
7 = Gray, rising
8 = binary, falling
9 = Gray, falling
6.2

Available lengths

To ensure flexible application,
nominal transducer lengths of from
50 to 4000 mm with following in-
crements are available:
S147: with connector, 7 pin
KA05: with 5 m cable
4 = 20 µm
5 = 40 µm
5.5

Fault conditions

When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
5.6

Noise elimination

Any difference in potential - current
flow - through the cable shield
should be avoided. Therefore:
– Use the isolation bushings, and
– Make sure the control cabinet
and the system in which the
BTL5 is contained are at the
same ground potential.
6 = 100 µm 7 = 2 Mm
Stroke lengths
[mm]
50 ... 1000
1000 ...
2000
2000 ...
4000
Other stroke lengths on request.
8 = 50 µm
Increments
[mm]
50
100
250
7